第1頁(yè)第2頁(yè)第3頁(yè)第4頁(yè)第5頁(yè)第6頁(yè)第7頁(yè)第8頁(yè)第9頁(yè)第10頁(yè)第11頁(yè)第12頁(yè)第13頁(yè)第14頁(yè)第15頁(yè)第16頁(yè)第17頁(yè)第18頁(yè)第19頁(yè)第20頁(yè)第21頁(yè)第22頁(yè)第23頁(yè)第24頁(yè)第25頁(yè)第26頁(yè)第27頁(yè)第28頁(yè)第29頁(yè)第30頁(yè)第31頁(yè)第32頁(yè)第33頁(yè)第34頁(yè)第35頁(yè)第36頁(yè)第37頁(yè)第38頁(yè)第39頁(yè)第40頁(yè)第41頁(yè)第42頁(yè)第43頁(yè)第44頁(yè)第45頁(yè)第46頁(yè)第47頁(yè)第48頁(yè)第49頁(yè)第50頁(yè)第51頁(yè)第52頁(yè)第53頁(yè)第54頁(yè)第55頁(yè)第56頁(yè)第57頁(yè)第58頁(yè)第59頁(yè)第60頁(yè)第61頁(yè)第62頁(yè)第63頁(yè)第64頁(yè)第65頁(yè)第66頁(yè)第67頁(yè)第68頁(yè)第69頁(yè)第70頁(yè)第71頁(yè)第72頁(yè)第73頁(yè)第74頁(yè)第75頁(yè)第76頁(yè)第77頁(yè)第78頁(yè)第79頁(yè)當(dāng)前第80頁(yè)第81頁(yè)第82頁(yè)第83頁(yè)第84頁(yè)第85頁(yè)第86頁(yè)第87頁(yè)第88頁(yè)第89頁(yè)第90頁(yè)第91頁(yè)第92頁(yè)第93頁(yè)第94頁(yè)第95頁(yè)第96頁(yè)第97頁(yè)第98頁(yè)第99頁(yè)第100頁(yè)第101頁(yè)第102頁(yè)第103頁(yè)第104頁(yè)第105頁(yè)第106頁(yè)第107頁(yè)第108頁(yè)第109頁(yè)第110頁(yè)第111頁(yè)第112頁(yè)第113頁(yè)第114頁(yè)第115頁(yè)第116頁(yè)第117頁(yè)第118頁(yè)第119頁(yè)第120頁(yè)第121頁(yè)第122頁(yè)第123頁(yè)第124頁(yè)第125頁(yè)第126頁(yè)第127頁(yè)第128頁(yè)第129頁(yè)第130頁(yè)第131頁(yè)第132頁(yè)第133頁(yè)第134頁(yè)第135頁(yè)第136頁(yè)第137頁(yè)第138頁(yè)第139頁(yè)第140頁(yè)第141頁(yè)第142頁(yè)第143頁(yè)第144頁(yè)第145頁(yè)第146頁(yè)第147頁(yè)第148頁(yè)第149頁(yè)第150頁(yè)
CD1865
Intelligent Eight-Channel Communications Controller
80
Datasheet
When the CD1865 is programmed to detect level changes and generate service requests when level
changes occur, it does so in firmware by reading the pins and comparing to a previously stored
value. This function is performed in the main timing loop of the firmware; the maximum time
required to detect a level change under worst-case conditions is approximately 2 ms. When the
CD1865 is performing this function, the modem pins are periodically sampled rather than
continuously monitored; as such they have very little sensitivity to noise, which is desirable in data
communication applications. However, in extremely noisy applications, re-read a modem line
which has caused a Modem Signal Change Service Request to verify that it has indeed changed and
is not merely malfunctioning. This eliminates even the slight possibility of a noise pulse causing
erratic operation.
When the CD1865 is monitoring modem pins to control transmit or receive functions, it does not
rely on the previously stored value, but checks the pins at the appropriate time. Thus, there is very
little delay in this response. For example, before deciding to transmit another character, it examines
the CTS* pin at that time. (The CD1865 makes this decision when moving characters from the
FIFO to the Holding register, not from the Holding register to the Shift register.) Refer to
Section 7.3 on page 72
for flow-control details.
Note that the logical sense of the modem bits is inverted; for example, writing a
1
to the MSVR
causes the output pin to go to nominal zero volts. Likewise, a low-voltage input is sensed as a
1
.
7.4.1
Generating Service Requests with Modem Pins
The CD1865 can generate service requests when any one of the input pins changes state. Either or
both edges may be detected by setting bits in the two Modem Change Option registers (MCOR1
and MCOR2). For each pin, the user can individually enable on-to-off or off-to-on transition
detection of the inputs. When the CD1865 detects such a transition, it sets the corresponding bit in
the Modem Change register. If the corresponding bit in the channel
s set, the CD1865 asserts its *
output. The user must clear the Modem Change register during the service request service routine
before writing to the .
The CD1865 performs this task by reading the modem input signals and comparing the current
value with the value read in the last pass through the outer scanning loop. Because this is the
lowest-priority event in the CD1865 scanning loop, changes may not be detected unless they are
several hundred microseconds long. Modem Input pins can be used for purposes such as detecting
the closing of a switch. However, the relatively slow speed of response should be taken into
account when using Modem Input pins for this purpose. The CD1865 does not latch the Modem
input signals.
7.4.2
Using Modem Pins as General-Purpose I/O
Since the modem pins can be directly accessed by the host, they can be used as general-purpose I/O
pins if they are not needed for flow control or modem interfacing. Simply read from and write to
them as any I/O port.
7.5
Testing the CD1865
Loopback Tests
The CD1865 performs a basic internal self-test whenever it is reset. This test provides a reasonable
degree of confidence that the CD1865 is functioning satisfactorily. There are two additional tests
that can be performed by the user to further ensure complete functionality. These two test modes
相關(guān)PDF資料
PDF描述
CD22100 CMOS 4 x 4 Crosspoint Switch with Control Memory High-Voltage Type (20V Rating)
CD22100E CMOS 4 x 4 Crosspoint Switch with Control Memory High-Voltage Type (20V Rating)
CD22100F CMOS 4 x 4 Crosspoint Switch with Control Memory High-Voltage Type (20V Rating)
CD22101 CMOS 4 x 4 x 2 Crosspoint Switch with Control Memory
CD22101E CMOS 4 x 4 x 2 Crosspoint Switch with Control Memory
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
CD1865N 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC
CD1865P 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC
CD1866N 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC
CD1866P 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC
CD1867N 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC