CHAPTER 17
IEBus CONTROLLER (
PD178096A, 178098A, 178F098 ONLY)
User’s Manual U12790EJ2V0UD
(2) Lock address
When the lock address is read (control bit: 4H or 5H), the address (12 bits) of the master unit that has issued
the lock instruction is configured in 1-byte units as shown below and read.
Figure 17-8. Configuration of Lock Address
MSB
Lower 8 bits
Undefined
Higher 4 bits
Control bit: 4H
Control bit: 5H
LSB
(3) Data
If the control bit indicates reading of data (3H or 7H), the data in the data buffer of the slave unit is read by the
master unit.
If the control bit indicates writing of data (BH or FH), the data received by the slave unit is processed according
to the operation rule of that slave unit.
(4) Locking and unlocking
The lock function is used when a message is transferred in two or more communication frames.
The unit that is locked does not receive data from units other than the one that has locked the unit (either individual
or broadcast communication).
A unit is locked or unlocked as follows.
(a) Locking
If the communication frame is completed without succeeding to transmit or receive data of the number of
bytes specified by the telegraph length bit after the telegraph length field has been transmitted or received
(ACK = 0) by the control bit that specifies locking (3H, AH, or BH), the slave unit is locked by the master
unit. At this time, the bit (bit 2) in the byte indicating the slave status is set to ‘1’.
(b) Unlocking
After transmitting or receiving data of the number of data bytes specified by the telegraph length bit in one
communication frame by the control bit that has specified locking (3H, AH, or BH), or the control bit that has
specified unlocking (6H), the slave unit is unlocked by the master unit. At this time, the bit related to locking
(bit 2) in the byte indicating the slave status is reset to ‘0’.
Locking or unlocking is not performed during broadcast communication.
The locking and unlocking conditions are shown below.