![](http://datasheet.mmic.net.cn/Exar-Corporation/XRT86VL30IV-F_datasheet_100157/XRT86VL30IV-F_139.png)
XRT86VL30
134
REV. 1.0.1
SINGLE T1/E1/J1 FRAMER/LIU COMBO - T1 REGISTER DESCRIPTION
TABLE 118: SS7 STATUS REGISTER FOR LAPD3 (SS7SR3)
HEX ADDRESS: 0X0B28
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
0
SS7_3_STATUS
RUR/
WC
0
SS7 Interrupt Status for LAPD Controller 3
This Reset-Upon-Read bit field indicates whether or not the “SS7”
interrupt has occurred since the last read of this register.
If this interrupt is enabled, then the Receive T1 Framer block will
generate an interrupt when the Received LAPD message is more
than 276 Bytes in length.
0 = Indicates that the “SS7” interrupt has not occurred since the last
read of this register
1 = Indicates that the “SS7” interrupt has occurred since the last
read of this register
TABLE 119: SS7 ENABLE REGISTER FOR LAPD3 (SS7ER3)
HEX ADDRESS: 0X0B29
BIT
FUNCTION
TYPE
DEFAULT
DESCRIPTION-OPERATION
0
SS7_3_ENB
R/W
0
SS7 Interrupt Enable for LAPD Controller 3
This bit enables or disables the “SS7” interrupt within the LAPD
Controller 3.
If this interrupt is enabled, then the Receive T1 Framer block will
generate an interrupt when the Received LAPD message is more
than 276 Bytes in length.
0 - Disables the “SS7” interrupt within the LAPD Controller 3.
1 - Enables the “SS7” interrupt within the LAPD Controller 3.