20. ELECTRICAL SPECIFICATIONS (TARGET VALUES)
Absolute Maximum Ratings (T
A
= 25°C, V
SS
= 0 V)
Parameter
Symbol
Conditions
Ratings
Unit
V
DD
–0.5 to +3.6
V
AV
DD
–0.5 to +3.6
V
EV
DD
–0.5 to +3.6
V
V
DD
BU
–0.5 to +3.6
V
AV
SS
–0.5 to +0.5
V
EV
SS
–0.5 to +0.5
V
Supply voltage
V
SS
BU
–0.5 to +0.5
V
Input voltage
V
I
Other than X1, XT1, and port 7
–0.5 to EV
DD
+ 0.3
Note
V
V
K
X1, V
DD
= 2.2 to 2.7 V
–0.5 to V
DD
+ 0.3
Note
V
Clock input voltage
V
KT
XT1, V
DD
BU = 2.2 to 2.7 V
–0.5 to V
DD
BU + 0.3
Note
V
Analog input voltage
V
IAN
Port 7
–0.5 to AV
DD
+ 0.3
Note
V
Analog reference voltage
AV
REF
AV
REF0
, AV
REF1
–0.5 to AV
DD
+ 0.3
Note
V
Per pin
4
mA
Output current, low
I
OL
Total for all pins
100
mA
Per pin
–4
mA
Output current, high
I
OH
Total for all pins
–100
mA
Output voltage
V
O
V
DD
= 2.5 V ±0.2 V
–0.5 to V
DD
+ 0.3 V
V
Normal operation mode
–40 to +85
°
C
Operating ambient
temperature
T
A
Flash programming mode
T.B.D.
°
C
μ
PD703201, 703201Y, 703204, 703204Y
–65 to +150
°
C
Storage temperature
T
stg
μ
PD70F3201, 70F3201Y, 70F3204,
70F3204Y
T.B.D.
°
C
Note
Be sure not to exceed the absolute maximum ratings (MAX. value) of each supply voltage.
Cautions
1. Do not directly connect the output (or I/O) pins of IC products to each other, or to V
DD
, V
CC
,
and GND. Open-drain pins or open-collector pins, however, can be directly connected to
each other. Direct connection of the output pins between an IC product and an external
circuit is possible, if the output pins can be set to the high-impedance state and the output
timing of the external circuit is designed to avoid output conflict.
2. Product quality may suffer if the absolute maximum rating is exceeded even momentarily for
any parameter. That is, the absolute maximum ratings are rated values at which the product
is on the verge of suffering physical damage, and therefore the product must be used under
conditions that ensure that the absolute maximum ratings are not exceeded.
The ratings and conditions indicated for DC characteristics and AC characteristics represent
the quality assurance range during normal operation.