––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– s ML53812-2 s
39
Oki Semiconductor
The Stream Switch provides a data stream-to-data stream connection capability. Switching between any
of the 32 CT Bus data streams operating at 2, 4, or 8 Mb/s is supported. Eight stream switch channels are
provided. Individual time-slots are not tri-state controlled. Buffering is done on single timeslots rather
than entire frames. This trade-off complicates the connection matrix, but without this compromise it
would not be practical to implement the Stream Switch.
Depending upon the data stream rates, the stream switch provides a minimum of 256 and a maximum of
1024 uni-directional timeslot connections. Stream switches in other ML53812-2 devices in a system may
be used simultaneously to increase switching capability. The output of the stream switch is multiplexed
with the output of the transmit switch, with the transmit switch having priority.
6.7 Stream Switch Connection Mapping
Input Data
Stream Rate
Output Data
Stream Rate
Partition
Timeslot Connection
2 Mb/s
0
0 to 1, 1 to 2, 2 to 3, … , 31 to 0
4 Mb/s
0
0 to 2, 1 to 4, 2 to 6, … , 31 to 0
1
0 to 3, 1 to 5, 2 to 7, … , 31 to 1
8 Mb/s
0
0 to 4, 1 to 8, 2 to 12, … , 31 to 0
1
0 to 5, 1 to 9, 2 to 13, … , 31 to 1
2
0 to 6, 1 to 10, 2 to 14, … , 31 to 2
3
0 to 7, 1 to 11, 2 to 15, … , 31 to 3
4 Mb/s
2 Mb/s
0
0 to 1, 2 to 2, 4 to 3, … , 62 to 0
1
1 to 1, 3 to 2, 5 to 3, … , 63 to 0
4 Mb/s
0
0 to 1, 1 to 2, 2 to 3, … , 63 to 0
8 Mb/s
0
0 to 2, 1 to 4, 2 to 6, … , 63 to 0
1
0 to 3, 1 to 5, 2 to 7, … , 63 to 1
8 Mb/s
2 Mb/s
0
0 to 1, 4 to 2, 8 to 3, … , 124 to 0
1
1 to 1, 5 to 2, 9 to 3, … , 125 to 0
2
2 to 1, 6 to 2, 10 to 3, … , 126 to 0
3
3 to 1, 7 to 2, 11 to 3, … , 127 to 0
4 Mb/s
0
0 to 1, 2 to 2, 4 to 3, … , 126 to 0
1
1 to 1, 3 to 2, 5 to 3, … , 127 to 0
8 Mb/s
0
0 to 1, 1 to 2, 2 to 3, … , 127 to 0
Frame Boundary
123
124
125
126
127
0123
4
CT_D time-slots @ 4mb/s
123
62
63
0
1
2
CT_D time-slots @ 2mb/s
30
31
0
1
CT_D time-slots @ 8mb/s
Figure 5. CT Bus Data Stream Switching