CAN BUS FAULT DIAGNOSTIC Once the error is detected t" />
參數(shù)資料
型號(hào): MCZ33905BD3EK
廠商: Freescale Semiconductor
文件頁數(shù): 64/106頁
文件大?。?/td> 0K
描述: IC SBC CAN HS 3.3V 54SOIC
標(biāo)準(zhǔn)包裝: 26
應(yīng)用: 系統(tǒng)基礎(chǔ)芯片
接口: CAN,LIN
電源電壓: 5.5 V ~ 28 V
封裝/外殼: 54-SSOP(0.295",7.50mm 寬)裸露焊盤
供應(yīng)商設(shè)備封裝: 54-SOICW-EP
包裝: 管件
安裝類型: 表面貼裝
Analog Integrated Circuit Device Data
60
Freescale Semiconductor
33903/4/5
CAN INTERFACE
CAN BUS FAULT DIAGNOSTIC
Once the error is detected the driver is disabled and the
error is reported via SPI in CAN register.
Recovery Condition
The internal recovery is done by sampling a correct low
level at TXD as shown in the following illustration.
Figure 40. RXD Path Simplified Schematic, RXD Short to VDD Detection
TXD PERMANENT DOMINANT
Principle
If the TXD is set to a permanent low level, the CAN bus is
set into dominant level, and no communication is possible.
The device has a TXD permanent timeout detector. After the
timeout (TDOUT), the bus driver is disabled and the bus is
released into a recessive state. The TXD permanent flag is
set.
Recovery
The TXD permanent dominant is used and activated when
there is a TXD short to RXD. The recovery condition for a
TXD permanent dominant (recovery means the re-activation
of the CAN drivers) is done by entering into a Normal mode
controlled by the MCU or when TXD is recessive while RXD
change from recessive to dominant.
TXD TO RXD SHORT-CIRCUIT
Principle
When TXD is shorted to RXD during incoming dominant
information, RXD is set to low. Consequently, the TXD pin is
low and drives CANH and CANL into a dominant state. Thus
the bus is stuck in dominant. No further communication is
possible.
Detection and Recovery
The TXD permanent dominant timeout will be activated and
release the CANL and CANH drivers. However, at the next
incoming dominant bit, the bus will then be stuck in dominant
again. The recovery condition is same as the TXD dominant
failure
IMPORTANT INFORMATION FOR BUS DRIVER
REACTIVATION
The driver stays disabled until the failure is/are removed
(TXD and/or RXD is no longer permanent dominant or
recessive state or shorted) and the failure flags cleared
(read). The CAN driver must be set by SPI in TXD/RXD mode
in order to re enable the CAN bus driver.
CANL&H
Diff output
RXD output
RXD short to VDD
RXD flag
RXD flag latched
Sampling
The RXD flag is not the RXPR bit in the LPC register, and neither is the CANF in the INTR register.
RXD no longer shorted to VDD
相關(guān)PDF資料
PDF描述
MCZ33972EWR2 IC SWITCH DETECTION MULT 32-SOIC
MCZ33975AEKR2 IC SWITCH DETECT MULT ENH 32SOIC
MCZ33993EWR2 IC MULTIPLE SWITCH DETECT 32SOIC
MCZ79076EGR2 IC IGNITION CTRL ELECTR 16-SOIC
MIC2070-2PCQS TR IC USB PWR CTRLR DUAL 16-QSOP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
MCZ33905BD3EKR2 功能描述:CAN 接口集成電路 3.3V SBC HSCAN DUAL LIN RoHS:否 制造商:Texas Instruments 類型:Transceivers 工作電源電壓:5 V 電源電流: 工作溫度范圍:- 40 C to + 85 C 封裝 / 箱體:SOIC-8 封裝:Tube
MCZ33905BD3R2 制造商:FREESCALE 制造商全稱:Freescale Semiconductor, Inc 功能描述:SBC Gen2 with CAN High Speed and LIN Interface
MCZ33905BD5EK 功能描述:CAN 接口集成電路 5.0V SBC HSCAN DUAL LIN RoHS:否 制造商:Texas Instruments 類型:Transceivers 工作電源電壓:5 V 電源電流: 工作溫度范圍:- 40 C to + 85 C 封裝 / 箱體:SOIC-8 封裝:Tube
MCZ33905BD5EKR2 功能描述:CAN 接口集成電路 5.0V SBC HSCAN DUAL LIN RoHS:否 制造商:Texas Instruments 類型:Transceivers 工作電源電壓:5 V 電源電流: 工作溫度范圍:- 40 C to + 85 C 封裝 / 箱體:SOIC-8 封裝:Tube
MCZ33905BD5R2 制造商:FREESCALE 制造商全稱:Freescale Semiconductor, Inc 功能描述:SBC Gen2 with CAN High Speed and LIN Interface