參數(shù)資料
型號: AX88796BLI
廠商: ASIX Electronics Corporation
英文描述: Low-pin-count Non-PCI 8/16-bit 10/100M Fast Ethernet Controller
中文描述: 低引腳數(shù)的非PCI 16位產(chǎn)品10/100M自適應快速以太網(wǎng)控制器
文件頁數(shù): 23/82頁
文件大?。?/td> 519K
代理商: AX88796BLI
ASIX ELECTRONICS CORPORATION
23
AX88796BLF / AX88796BLI
4.2.5 Other Useful Operations
Memory Diagnostics
Memory diagnostics can be achieved by Remote Write/Read DMA operations. The following is a suggested step for
memory test and assume the AX88796B has been well initialized.
1.
Issue the STOP command to the AX88796B. This is accomplished be setting the STP bit in the AX88796B's
Command Register. Writing 21H to the Command Register will stop the AX88796B.
2.
Wait for at least 1.5 ms. Since the AX88796B will complete any reception that is in progress, it is necessary
to time out for the maximum possible duration of an Ethernet reception. This action prevents buffer memory
from written data through Local DMA Write.
3.
Write data pattern to MUT (memory under test) by Remote DMA write operation.
4.
Read data pattern from MUT (memory under test) by Remote DMA read operation.
5.
Compare the read data pattern with original write data pattern and check if it is equal.
6.
Repeat step 3 to step 5 with various data pattern.
Loop-back Diagnostics
1.
Issue the STOP command to the AX88796B. This is accomplished be setting the STP bit in the AX88796B's
Command Register. Writing 21h to the Command Register will stop the AX88796B.
2.
Wait for at least 1.5 ms. Since the AX88796B will complete any reception that is in progress, it is necessary
to time out for the maximum possible duration of an Ethernet reception. This action prevents buffer memory
from written data through Local DMA Write.
3.
Place the AX88796B in mode 1 loop-back. (MAC internal loop-back) This can be accomplished by setting
LB1 and LB0, of the Transmit Configuration Register to ``0,1''.
4.
Issue the START command to the AX88796B. This can be accomplished by writing 22h to the Command
Register. This is necessary to activate the AX88796B's Remote DMA channel.
5.
Write data that want to transmit to transmit buffer by Remote DMA write operation.
6.
Issue the TXP command to the AX88796B. This can be accomplished by writing 26h to the Command
Register.
7.
Read data current receive buffer by Remote DMA read operation.
8.
Compare the received data with original transmit data and check if it is equal.
9.
Repeat step 5 to step 8 for more packets test.
相關PDF資料
PDF描述
AX88872P 10/100BASE Dual Speed “Swipeater” Controller
AX9902MS 2N and 2P-Channel Enhancement Mode Power MOSFET
AX9902MSA 2N and 2P-Channel Enhancement Mode Power MOSFET
AXC-051 ACTIVE FILTER FOR RIPPLE ATTENUATION 5A
AXC-051-R ACTIVE FILTER FOR RIPPLE ATTENUATION 5A
相關代理商/技術參數(shù)
參數(shù)描述
AX88796C 制造商:ASIX 制造商全稱:ASIX 功能描述:Low-Power SPI or Non-PCI Ethernet Controller
AX88796CLF 制造商:ASIX Electronics Corporation 功能描述:
AX88796L 制造商:ASIX 制造商全稱:ASIX 功能描述:3-in-1 Local Bus Fast Ethernet Controller
AX88796LF 制造商:ASIX 功能描述:10/100 MAC
AX88850 制造商:ASIX 制造商全稱:ASIX 功能描述:100BASE-TX/FX Repeater Controller