![](http://datasheet.mmic.net.cn/190000/UPD780123GB-A1--XXX-8ET_datasheet_14990904/UPD780123GB-A1--XXX-8ET_138.png)
CHAPTER 6 16-BIT TIMER/EVENT COUNTER 00
User’s Manual U16315EJ3V1UD
138
Figure 6-7. Format of 16-Bit Timer Output Control Register 00 (TOC00)
Address: FFBDH
After reset: 00H
R/W
Symbol
7
<6>
<5>
4
<3>
<2>
1
<0>
TOC00
0
OSPT00
OSPE00
TOC004
LVS00
LVR00
TOC001
TOE00
OSPT00
One-shot pulse output trigger control via software
0
No one-shot pulse output trigger
1
One-shot pulse output trigger
OSPE00
One-shot pulse output operation control
0
Successive pulse output mode
1
One-shot pulse output mode
Note
TOC004
Timer output F/F control using match of CR010 and TM00
0
Disables inversion operation
1
Enables inversion operation
LVS00
LVR00
Timer output F/F status setting
0
No change
0
1
Timer output F/F reset (0)
1
0
Timer output F/F set (1)
1
Setting prohibited
TOC001
Timer output F/F control using match of CR000 and TM00
0
Disables inversion operation
1
Enables inversion operation
TOE00
Timer output control
0
Disables output (output fixed to level 0)
1
Enables output
Note The one-shot pulse output mode operates correctly only in the free-running mode and the mode in which
clear & start occurs at the TI000 valid edge. In the mode in which clear & start occurs on a match between
the TM00 register and CR000 register, one-shot pulse output is not possible because an overflow does not
occur.
Cautions 1. Timer operation must be stopped before setting other than TOC004.
2. If LVS00 and LVR00 are read, 0 is read.
3. OSPT00 is automatically cleared after data is set, so 0 is read.
4. Do not set OSPT00 to 1 other than in one-shot pulse output mode.
5. A write interval of two cycles or more of the count clock selected by prescaler mode register
00 (PRM00) is required to write to OSPT00 successively.
6. Do not set LVS00 to 1 before TOE00, and do not set LVS00 and TOE00 to 1 simultaneously.
7. Perform <1> and <2> below in the following order, not at the same time.
<1> Set TOC001, TOC004, TOE00, OSPE00: Timer output operation setting
<2> Set LVS00, LVR00: Timer output F/F setting