![](http://datasheet.mmic.net.cn/370000/UPD6708_datasheet_16740712/UPD6708_40.png)
40
μ
PD6708
Table 6-4. Return Codes in Broadcast Reception
Return Code Name
Code
Description
Broadcast reception start
1100
This return code is generated when the slave unit correctly receives the
message length codes from the master unit, informing the host controller of
the start of slave reception.
Broadcast receive data full
1101
Each time 20 bytes (RDB capacity) of slave receive data is received, if RDB is
full, this return code makes a request to the host controller for a read of receive
data from RDB.
Broadcast reception normal
termination
1110
Indicates that reception of the number of data bytes specified by the message
length bits has ended within one frame.
Termination during broadcast
reception
1111
Indicates that the communication has ended without completion of transmis-
sion of the number of data bytes specified by the message length bits within
one frame.
6.5
Return Codes Generation Intervals
This section describes the generation order and the minimum generation interval for return codes generated each time
communication is performed,
Each time a new return code is generated, it is placed in STR without regard to STR read. For this reason, the host
controller must take account of the minimum return code generation interval in controlling the
μ
PD6708.
(1)
Master transmission
After execution of the MREQ1 or MREQ2 command, the order of generation of master transmission return codes is as
shown in Figure 6-1.
Figure 6-1. Return Code Generation Order in Master Transmission
The minimum generation intervals for return codes in master transmission are shown below.
Table 6-5. Minimum Generation Intervals for Return Codes in Master Transmission (
μ
s)
Time
Mode 0
Mode 1
Mode 2
T1
Approx. 6325
Approx. 1605
Approx. 1160
T2
Approx. 10
Approx. 10
Approx. 10
T3
Approx. 7290
Approx. 2050
Approx. 1550
Transmission Start
(Return Code : 0000)
Termination During
Transmission
(Return Code : 0011)
Transmission
Normal Termination
(Return Code : 0010)
Termination During
Transmission
(Return Code : 0011)
T3
T3
T3
New communication return codes
Slave reception start
(Return code : 1000)
Broadcast reception start
(Return code : 1100)
etc.
T1
T2