COMMAND DEFINITIONS
The commands summarized in
Table 19 control and configure the operation of the ADS1259. The commands
are stand-alone, except for the register read and register write operations which require a second command byte
plus data. CS can be taken high or held low between opcode commands but must stay low for the entire
command operation. Note that the Read Data Continuous mode must be cancelled by the Stop Read Data
Continuous mode opcode (SDATAC) before sending further commands.
Table 19. Command Definitions(1)
COMMAND
TYPE
DESCRIPTION
FIRST OPCODE BYTE
SECOND OPCODE BYTE
WAKEUP
Control
Wake up from SLEEP mode
0000 001x (02h or 03h)(2)
SLEEP
Control
Begin SLEEP mode
0000 010x (04h or 05h)(2)
RESET
Control
Reset to power-up values
0000 011x (06h or 07h)(2)
START
Control
START conversion
0000 100x (08h or 09h)(2)
STOP
Control
STOP conversion
0000 101x (0Ah or 0Bh)(2)
RDATAC
Control
Set Read Data Continuous mode
0001 0000 (10h)
SDATAC
Control
Stop Read Data Continuous mode
0001 0001 (11h)
RDATA
Data
Read data by opcode
0001 001x (12h or 13h)(2)
RREG
Register
Read nnnn register at address rrrr
0010 rrrr (20h + 0000 rrrr)
0000 nnnn (00h + nnnn)
WREG
Register
Write nnnn register at address rrrr
0100 rrrr (40h + 0000 rrrr)
0000 nnnn (00h + nnnn)
OFSCAL
Calibration
Offset calibration
0001 1000 (18h)
GANCAL
Calibration
Gain calibration
0001 1001 (19h)
(1)
nnnn = number of registers to be read/written
– 1. For example, to read/write 3 registers, set nnnn = 2 (0010).
rrrr = starting register address for read/write opcodes.
(2)
These commands are decoded on the seventh bit of the opcode. The eighth bit is a don
't care bit. All other commands are decoded on
the eighth bit.
WAKEUP: Exit SLEEP Mode
Description: This command exits the low-power SLEEP mode; see the
SLEEP Mode section.
SLEEP: Enter SLEEP Mode
Description: This command enters the low-power SLEEP mode. See the
SLEEP Mode section.
RESET: Reset Registers to Default Values
Description: This command resets the digital filter cycle and returns all register settings to the default values.
START: Start Conversions
Description: This command starts data conversions. If PULSE bit = 1, then a single conversion is performed. If
PULSE bit = 0, then conversions continue until the STOP command is sent. Tie the START pin low to control
conversions by command.
STOP: Stop Conversions
Description: This command stops conversions. When the STOP command is sent, the conversion in progress
completes and further conversions are stopped. If conversions are already stopped, this command has no effect.
See the
Conversion Control section. Tie the START pin low to control conversions by command.
RDATAC: Read Data Continuous
Description: This command enables the Read Data Continuous mode (default). See the
Read Data Continuous Mode section for details. Disable this mode with the SDATAC command before sending other commands.
SDATAC: Stop Read Data Continuous
Description: This command cancels the Read Data Continuous mode.