Table 2. Input Monitor Ranges and Enables
REGISTER/
EEPROM
ADDRESS
BIT RANGE
DESCRIPTION
[1:0]
MON1 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON1 is not converted or monitored
[3:2]
MON2 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON2 is not converted or monitored
[5:4]
MON3 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON3 is not converted or monitored
0Fh
[7:6]
MON4 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON4 is not converted or monitored
[1:0]
MON5 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON5 is not converted or monitored
[3:2]
MON6 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON6 is not converted or monitored
[5:4]
MON7 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON7 is not converted or monitored
10h
[7:6]
MON8 Voltage Range Selection:
00 = From 0 to 5.6V in 5.46mV steps
01 = From 0 to 2.8V in 2.73mV steps
10 = From 0 to 1.4V in 1.36mV steps
11 = MON8 is not converted or monitored
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers