參數(shù)資料
型號: M29W320DB7AN6
廠商: NUMONYX
元件分類: PROM
英文描述: 2M X 16 FLASH 3V PROM, 70 ns, PDSO48
封裝: 12 X 20 MM, PLASTIC, TSOP-48
文件頁數(shù): 9/56頁
文件大?。?/td> 1125K
代理商: M29W320DB7AN6
M29W320DT, M29W320DB
Command Interface
17/56
4
Command Interface
All Bus Write operations to the memory are interpreted by the Command Interface.
Commands consist of one or more sequential Bus Write operations. Failure to observe a
valid sequence of Bus Write operations will result in the memory returning to Read mode.
The long command sequences are imposed to maximize data security.
The address used for the commands changes depending on whether the memory is in 16-
bit or 8-bit mode. See either Table 4, or Table 5, depending on the configuration that is being
used, for a summary of the commands.
4.1
Read/Reset command
The Read/Reset command returns the memory to its Read mode where it behaves like a
ROM or EPROM, unless otherwise stated. It also resets the errors in the Status Register.
Either one or three Bus Write operations can be used to issue the Read/Reset command.
The Read/Reset Command can be issued, between Bus Write cycles before the start of a
program or erase operation, to return the device to read mode. Once the program or erase
operation has started the Read/Reset command is no longer accepted. The Read/Reset
command will not abort an Erase operation when issued while in Erase Suspend.
4.2
Auto Select command
The Auto Select command is used to read the Manufacturer Code, the Device Code and the
Block Protection Status. Three consecutive Bus Write operations are required to issue the
Auto Select command. Once the Auto Select command is issued the memory remains in
Auto Select mode until a Read/Reset command is issued. Read CFI Query and Read/Reset
commands are accepted in Auto Select mode, all other commands are ignored.
From the Auto Select mode the Manufacturer Code can be read using a Bus Read
operation with A0 = VIL and A1 = VIL. The other address bits may be set to either VIL or VIH.
The Manufacturer Code for Numonyx is 0020h.
The Device Code can be read using a Bus Read operation with A0 = VIH and A1 = VIL. The
other address bits may be set to either VIL or VIH. The Device Code for the M29W320DT is
22CAh and for the M29W320DB is 22CBh.
The Block Protection Status of each block can be read using a Bus Read operation with A0
= VIL, A1 = VIH, and A12-A20 specifying the address of the block. The other address bits
may be set to either VIL or VIH. If the addressed block is protected then 01h is output on
Data Inputs/Outputs DQ0-DQ7, otherwise 00h is output.
相關PDF資料
PDF描述
M30L40C-E3/4W 15 A, 40 V, SILICON, RECTIFIER DIODE, TO-220AB
M31012ABMNFREQ VCXO, CLOCK, 150 MHz - 1400 MHz, CMOS OUTPUT
M31002ABPNFREQ VCXO, CLOCK, 150 MHz - 1400 MHz, PECL OUTPUT
M31002BSLNFREQ VCXO, CLOCK, 150 MHz - 1400 MHz, LVDS OUTPUT
M31022AGPNFREQ VCXO, CLOCK, 150 MHz - 1400 MHz, PECL OUTPUT
相關代理商/技術參數(shù)
參數(shù)描述
M29W320DB7AN6E 制造商:Micron Technology Inc 功能描述:AUTOMOTIVE - Trays 制造商:Micron Technology Inc 功能描述:IC FLASH 32MBIT 70NS 48TSOP
M29W320DB7AN6F 制造商:Micron Technology Inc 功能描述:AUTOMOTIVE - Tape and Reel
M29W320DB7AN6F TR 制造商:Micron Technology Inc 功能描述:IC FLASH 32MBIT 70NS 48TSOP
M29W320DB7AZA3F 制造商:Micron Technology Inc 功能描述:AUTOMOTIVE - Tape and Reel
M29W320DB7AZA6E 制造商:Micron Technology Inc 功能描述:32MB 2MX16 NOR FLASH PLASTIC IND TEMP BOTTOM PBF TFBGA 3.0V - Trays 制造商:Micron Technology Inc 功能描述:IC FLASH 32MBIT 70NS 63TFBGA