SN54ALVTH16245, SN74ALVTH16245
2.5-V/3.3-V 16-BIT BUS TRANSCEIVERS
WITH 3-STATE OUTPUTS
SCES066A – JUNE 1996 – REVISED JULY 1996
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
Input voltage range, V
I
(see Note 1)
Voltage range applied to any output in the high state or power-off state, V
O
(see Note 1)
Output current in the low state, I
O
:SN54ALVTH16245
SN74ALVTH16245
Output current in the high state, I
O
: SN54ALVTH16245
SN74ALVTH16245
Input clamp current, I
IK
(V
I
< 0)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum power dissipation at T
A
= 55
°
C (in still air) (see Note 2):DGG package
–0.5 V to 4.6 V
–0.5 V to 7 V
–0.5 V to 7 V
. . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
96 mA
128 mA
–48 mA
–64 mA
–50 mA
–50 mA
0.85 W
0.87 W
1.2 W
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
DGV package
DL package
Storage temperature range, T
stg
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150
°
C and a board trace length of 750 mils.
For more information, refer to the Package Thermal Considerationsapplication note in the ABT Advanced BiCMOS Technology Data
Book
recommended operating conditions, V
CC
= 2.5 V
±
0.2 V (see Note 3)
–65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN54ALVTH16245
MIN
2.3
1.7
SN74ALVTH16245
MIN
2.3
1.7
UNIT
MAX
2.7
MAX
2.7
VCC
VIH
VIL
VI
IOH
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
High-level output current
Low-level output current
Low-level output current; current duty cycle
≤
50%; f
≥
1 KHz
Input transition rise or fall rate
Operating free-air temperature
V
V
V
V
0.7
5.5
–6
0.7
5.5
–8
0
0
mA
IOL
6
8
mA
18
10
125
24
10
85
t/
v
TA
NOTE 3: Unused control inputs must be held high or low to prevent them from floating.
Outputs enabled
ns/V
°
C
–55
–40
P