GENNUM CORPORATION
20582 - 3
2 of 14
G
ABSOLUTE MAXIMUM RATINGS
PARAMETER
VALUE
Supply Voltage (V
S
)
5.5V
Input Voltage Range (any input)
V
CC
+ 0.5 to V
EE
- 0.5V
Operating Temperature Range
0°C
≤
T
A
≤
70°C
Storage Temperature Range
-65°C
≤
T
S
≤
150°C
Lead Temperature (soldering, 10 sec)
260°C
DC ELECTRICAL CHARACTERISTICS
V
CC
= 5.0V, V
EE
= 0V, T
A
= 0°C to 70°C unless otherwise stated, R
LF
= 1.8K, C
LF1
= 15nF, C
LF2
= 3.3pF.
PARAMETER
CONDITION
MIN
TYPICAL
1
MAX
UNITS
NOTES
TEST
LEVEL
Supply Voltage
4.75
5.00
5.25
V
3
Supply Current
CLK_EN = 0
-
90
110
mA
3
CLK_EN = 1
-
105
120
mA
3
DDI/DDI Common Mode Input
Voltage Range
V
EE
+ (V
DIFF
/2)
0.4 to 4.6
V
CC
- (V
DIFF
/2)
V
2
3
DDI/DDI Differential Input
Drive
200
800
2000
mV
3
AUTO/MAN, SMPTE
High
2.0
-
-
V
3
Low
-
-
0.8
CLK_EN Input Voltage
High
2.5
-
-
V
3
Low
-
-
0.8
LOCK Output Low Voltage
Ι
OH
=
500μA
-
0.25
0.4
V
3
1
SS[1:0] Output Voltage
HIGH,
Ι
OH
= -180μA,
Auto Mode
4.4
4.8
-
V
1
LOW,
Ι
OL
=
600μA,
Auto Mode
-
0.3
0.4
SS[1:0] Input Voltage
HIGH, Manual Mode
2
-
-
V
3
LOW, ManualMode
-
-
0.8
CLK_EN Source Current
Low, V
IL
= 0V
-
26
55
μA
1
NOTES
1. TYPICAL - measured on EB-RD35A board.
2. V
DIFF
is the differential input signal swing.
3. LOCK is an open collector output and requires an
external pull-up resistor.
4. Pins SS[1:0] are outputs in AUTO mode and inputs in
MANUAL mode.
TEST LEVELS
1. Production test at room temperature and nominal supply voltage with
guardbands for supply and temperature ranges.
2. Production test at room temperature and nominal supply voltage with
guardbands for supply and temperature ranges using correlated test.
3. Production test at room temperature and nominal supply voltage.
4. QA sample test.
5. Calculated result based on Level 1,2, or 3.
6. Not tested. Guaranteed by design simulations.
7. Not tested. Based on characterization of nominal parts.
8. Not tested. Based on existing design/characterization data of similar
product.
9. Indirect Test.
10.Production test at room temperature.