參數(shù)資料
型號: CT1775
廠商: Aeroflex Inc.
英文描述: CT1775 Universal MacAir/1553 Dumb RTU Hybrid
中文描述: CT1775通用MacAir/1553啞RTU的混合
文件頁數(shù): 5/14頁
文件大?。?/td> 184K
代理商: CT1775
5
SCDCT1775 Rev B
OUTPUT FLAGS
The CT1775 provides numerous output flags to offer the
greatest user flexibility.
VALID WORD
indicates receipt of a
word with valid sync, Manchester coding and parity.
RT
ENABLE
indicates a valid word and correct address.
VAL
CMD WD
indicates a valid word and a Command Sync.
BROADCAST indicates a valid command word and an address
of 11111. The BROADCAST flag may be inhibited by using
the
BDCST INHIBIT
line.
MODE CODE
indicates a valid
command word and a subaddress of 11111 or 00000.
INITIALIZATION
To ensure error-free operation, it is desirable to reset the
CT1775 to its initialized state upon power turn-on. The
MRST
(master reset) signal is provided for this purpose. Both the
flecoder and encoder, as well as all flags, are reset by a LOW
on
MRST
. This function interrupts and overrides all other
control signals. The
MRST
function can also be sued during
fault recovery routines.
TRANSCEIVER OPERATION
The CT1775 contains a transceiver similar to Aeroflex model
CT3232. When connected to a serial MUX data bus via
transformer and isolation resistors, as shown in Figure 6, the
CT1775 transceiver will fully comply with MIL-STD-1553.
The correct Technitrol part numbers for transformers used in
direct-coupled and transformercoupled operation are shown in
Figure 6.
Transceiver
TX INHIBIT
and
RX STROBE
signals are
provided to afford flexible operation. These signals may be
used to disable the transmitter and receiver, respectively.
ENCODER OPERATION
Figure 2 illustrates the transmit mode timing. Encoder detail
timing is shown in Figure 4. The transmit cycle is initiated by a
LOW on
ENC ENABLE
. The first HIGH to LOW (falling
edge) transition of ESC OUT, when
ENC ENABLE
is LOW,
starts the cycle which lasts for 20 clock periods of the 1 MHz
ESC OUT. The next LOW to HIGH transition of ESC OUT
strobes the
SYNC SELECT
line. A HIGH on
SYNC SELECT
produces a data sync and a LOW produces a command/status
sync.
A LOW to HIGH transition of SEND DATA occurs at the
fourth falling edge of ESC OUT. This indicates the completion
of the sync interval and the start of the serial data interval.
Parallel data must be stable at the second rank transmit register
prior to the rising edge of SEND DATA, which occurs 3
microseconds (minimum) after the HIGH to LOW transition of
ENC ENABLE
. LATCH DATA is used to transfer parallel data
to the first rank transmit register. LATCH DATA must be
brought LOW and
DATA SELECT
brought HIGH prior to the
rising edge of SEND DATA. If SEND DATA is connected
directly to
LOAD DATA
, it will lock out the second rank
transmit register and serial data shifting into the encoder will
proceed properly.
For multiple word transmissions, the next word may be
transferred to the transmit register any time after SEND DATA
goes HIGH, but no later than the next LOW to HIGH transition
of SEND DATA. SEND DATA remains HIGH for 16 periods
of ESC OUT, during which time the data word is serially
shifted to the Manchester encoder. The encoder adds the parity
bit during the next ESC OUT period after SEND DATA goes
LOW. To terminate transmission after any word,
ENC
ENABLE
must go to HIGH no later than the first rising edge of
ESC OUT after SEND DATA goes LOW.
The entire transmit cycle may be interrupted and initialized by
applying a 1 microsecond (minimum) negative pulse to
MRST
.
It is possible to input data to the encoder in serial form by
forcing both transmit registers to be transparent. With LATCH
DATA 1 held HIGH and
LOAD DATA 1
held LOW, serial data
input on D15 will be applied directly to the encoder serial
input. ESC OUT must be used to shift in the serial data, MSB
first, starting at the LOW to HIGH transition of SEND DATA.
DECODER OPERATION
Figure 3 illustrates the receive mode timing. Decoder detail
timing is shown in Figure 5. A receive cycle, which lasts for 20
clock periods of the 1 MHz DSC OUT, is initiated when the
decoder recognizes a valid sync and two valid Manchester data
bits.
TAKE DATA
goes LOW at the first HIGH to LOW
(falling edge) transition of DSC OUT, following the second
valid dat bit. COMM/
DATA
SYNC is updated at the next
rising edge of DSC OUT after
TAKE DATA
goes LOW.
COM/
DATA
SYNC remains in its new state until the next valid
word or until
DEC RST
or
MRST
goes LOW.
TAKE DATA
remains LOW for 16 periods of DSC OUT,
during which time the 16 serial data bits are shifted into the
first rank receive register. The serial data is simultaneously
available at SERIAL DATA OUT as it is being shifted. At the
completion of decoded data shifting,
TAKE DATA
goes HIGH,
which transfers the data to the second rank receive register.
This data may be enabled onto the parallel data highway by
LOW on
DATA SELECT
at any time until the next rising edge
of
TAKE DATA
.
At the first rising edge of DSC OUT after
TAKE DATA
goes
HIGH,
VALID WORD
is updated. It will go LOW if the
decoded word was valid.
VALID WORD
will go HIGH at the
start of the next receive cycle, or after 20 microseconds if no
additional words ar received. All output flags are enabled by
VALID WORD
, and therefore they are valid only as long as
VALID WORD
is LOW.
相關(guān)PDF資料
PDF描述
CT1815 CT1815 10MHz Low Level Serial Interface for MIL-STD-1397 Type D
CT1815FP CT1815 10MHz Low Level Serial Interface for MIL-STD-1397 Type D
CT1820 CT1820 Data Terminal Bit Processor for MIL-STD-1553 A & B
CT1991-1-20 MIL-STD-1553B Remote Terminal, Bus Controller, or Passive Monitor Hybrid with Status Word Control
CT1990-1-20 MIL-STD-1553B Remote Terminal, Bus Controller, or Passive Monitor Hybrid with Status Word Control
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
CT-18 功能描述:HIGH CURRENT 18 CIRC BLOCK RoHS:是 類別:連接器,互連式 >> 接線座 - 隔板塊 系列:CT 標(biāo)準(zhǔn)包裝:10 系列:Beau™ 38780 端接塊類型:阻隔塊 電路數(shù):15 導(dǎo)線入口數(shù)目:30 間距:0.438"(11.12mm) 行數(shù):2 電流:15A 電壓:300V 線規(guī):14-22 AWG 頂部端子:螺釘 底部端子:焊片 阻擋層類型:雙壁(雙) 特點:法蘭 顏色:黑 包裝:散裝 安裝類型:通孔 工作溫度:- 材料 - 絕緣體:聚對苯二甲酸丁二酯(PBT),玻璃纖維增強(qiáng)型 材料可燃性額定值:UL94 V-0 其它名稱:038780-111538780-1115387801115
CT1800 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Telecommunication IC
CT1800FP 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU
CT1801 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Telecommunication IC
CT1801FP 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU