![](http://datasheet.mmic.net.cn/Analog-Devices-Inc/AD8352ACPZ-R7_datasheet_108082/AD8352ACPZ-R7_5.png)
AD8352
Rev. B | Page 5 of 20
Parameter
Conditions
Min
Typ
Max
Unit
190 MHz
Second/Third Harmonic Distortion
RL = 1 kΩ, VOUT = 2 V p-p
82/85
dBc
RL = 200 Ω, VOUT = 2 V p-p
81/87
dBc
Output Third-Order Intercept
RL = 200 Ω, f1 = 180.5 MHz, f2 = 190.5 MHz
39
dBm
Third-Order IMD
RL = 1 kΩ, f1 = 180.5 MHz, f2 = 190.5 MHz,
VOUT = 2 V p-p composite
83
dBc
RL = 200 Ω, f1 = 180.5 MHz, f2 = 190.5 MHz,
VOUT = 2 V p-p composite
81
dBc
Noise Spectral Density (RTI)
2.7
nV/√Hz
1 dB Compression Point (RTO)
15.4
dBm
240 MHz
Second/Third Harmonic Distortion
RL = 1 kΩ, VOUT = 2 V p-p
82/76
dBc
RL = 200 Ω, VOUT = 2 V p-p
80/73
dBc
Output Third-Order Intercept
RL = 200 Ω, f1 = 239.5 MHz, f2 = 240.5 MHz
36
dBm
Third-Order IMD
RL = 1 kΩ, f1 = 239.5 MHz, f2 = 240.5 MHz,
VOUT = 2 V p-p composite
85
dBc
RL = 200 Ω, f1 = 239.5 MHz, f2 = 240.5 MHz,
VOUT = 2 V p-p composite
77
dBc
Noise Spectral Density (RTI)
2.7
nV/√Hz
1 dB Compression Point (RTO)
15.3
dBm
380 MHz
Second/Third Harmonic Distortion
2RL = 1 kΩ, VOUT = 2 V p-p
72/68
dBc
RL = 200 Ω, VOUT = 2 V p-p
74/69
dBc
Output Third-Order Intercept
RL = 200 Ω, f1 = 379.5 MHz, f2 = 380.5 MHz
33
dBm
Third-Order IMD
RL = 1 kΩ, f1 = 379.5 MHz, f2 = 380.5 MHz,
VOUT = 2 V p-p composite
74
dBc
RL = 200 Ω, f1 = 379.5 MHz, f2 = 380.5 MHz,
VOUT = 2 V p-p composite
70
dBc
Noise Spectral Density (RTI)
2.7
nV/√Hz
1 dB Compression Point (RTO)
14.6
dBm
500 MHz
Second/Third Harmonic Distorti
on2RL = 200 Ω, VOUT = 2 V p-p
71/64
dBc
Output Third-Order Intercept
RL = 200 Ω, f1 = 499.5 MHz, f2 = 500.5 MHz
28
dBm
Third-Order IMD
RL = 200 Ω, f1 = 499.5 MHz, f2 = 500.5 MHz,
VOUT = 2 V p-p composite
61
dBc
Noise Spectral Density (RTI)
2.7
nV/√Hz
1 dB Compression Point (RTO)
13.9
dBm
1 When using the evaluation board at frequencies below 50 MHz, replace the Output Balun T1 with a transformer, such as Mini-Circuits ADT1-1WT to obtain the low
frequency balance required for differential HD2 cancellation.
2 CD and RD can be optimized for broadband operation below 180 MHz. For operation above 300 MHz, CD and RD components are not required.