Read Operation
As with the self-clocking mode, data can be read from either the
output register, the control register or the calibration registers.
A0 determines whether the data read accesses data from the
control register or from the output/calibration registers. This A0
signal must remain valid for the duration of the serial read
operation. With A0 high, data is accessed from either the output
register or from the calibration registers. With A0 low, data is
accessed from the control register.
The function of the
DRDY
line is dependent only on the output
update rate of the device and the reading of the output data
register.
DRDY
goes low when a new data word is available in
the output data register. It is reset high when the last bit of data
(either 16th bit or 24th bit) is read from the output register. If
data is not read from the output register, the
DRDY
line will
remain low. The output register will continue to be updated at
the output update rate but
DRDY
will not indicate this. A read
from the device in this circumstance will access the most recent
word in the output register. If a new data word becomes avail-
able to the output register while data is being read from the
output register,
DRDY
will not indicate this and the new data
word will be lost to the user.
DRDY
is not affected by reading
from the control register or the calibration register.
Data can only be accessed from the output data register when
DRDY
is low. If
RFS
goes low while
DRDY
is high, no data
transfer will take place.
DRDY
does not have any effect on read-
ing data from the control register or from the calibration
registers.
Write Operation
Data can be written to either the control register or calibration
registers. In either case, the write operation is not affected by
the
DRDY
line and the write operation does not have any effect
on the status of
DRDY
. A write operation to the control register
or the calibration register must always write 24 bits to the re-
spective register.
Figure 11 shows a write operation to the AD7710. A0 deter-
mines whether a write operation transfers data to the control
register or to the calibration registers. This A0 signal must re-
main valid for the duration of the serial write operation. The
falling edge of
TFS
enables the internally generated SCLK
output. The serial data to be loaded to the AD7710 must be
valid on the rising edge of this SCLK signal. Data is clocked
into the AD7710 on the rising edge of the SCLK signal with the
MSB transferred first. On the last active high time of SCLK, the
LSB is loaded to the AD7710. Subsequent to the next falling
edge of SCLK, the SCLK output is turned off. (The timing
diagram of Figure 11 assumes a pull-up resistor on the SCLK
line.)
External Clocking Mode
The AD7710 is configured for its external clocking mode by
tying the MODE pin low. In this mode, SCLK of the AD7710
is configured as an input and an external serial clock must be
provided to this SCLK pin. This external clocking mode is
designed for direct interface to systems which provide a serial
clock output that is synchronized to the serial data output,
including microcontrollers such as the 80C51, 87C51, 68HC11
and 68HC05 and most digital signal processors.
SDATA (I)
SCLK (O)
TFS (I)
A0 (I)
t
14
t
15
t
18
t
19
t
10
9
t
t
16
MSB
LSB
t
17
Figure 11. Self-Clocking Mode, Control/Calibration Register Write Operation