NEW
WIRING DIAGRAM
BOTTOM VIEWS
1270 Max.
(32.26)
1.080 Max.
(27.43)
1.10 Max.
(27.94)
OUTLINE DIMENSIONS
(Actual Size)
Dimensions are in "inches" & (Millimeters)
.032 x .62
(.81 x 1.57)
.045 x .045
(1.14 x 1.14)
.025 x .025
(.63 x .63)
2 places
.130
±
.020
(3.30
±
.51)
1.980 Max.
(50.29)
1.713
±
.010
(43.51
±
.25)
1.27 Max.
(32.26)
B1
B1
.071Rad. (1.80) For #6 screw ( 2 places)
N
N
C
N
N
C
FIGURE
"A"
P.C.
MOUNT
A1
B1
B1
A1
A1
A1
A1
A1
A1 = .250 X .032 (6.35 X .81) Quick Connect Terminal
B1 = .187 x .020 (4.78 x .508) Quick Connect Terminal
FIGURE
"B"
FLANGE
MOUNT
C L A S S
30 AMP PC or FLANGE MOUNT MINIATURE RELAY
C US
UL Recognized
File No. E43641
SPST-NO
SPDT
Recognized Component mark for
Canada and the United States.
9A
PAGE 49
.250 Max.
(6.35)
.500
(12.7)
.140 Max.
(3.56)
.150
(3.81)
.700
(17.8)
A
A
A
B
B
.600
(15.24)
.300
(7.62)
.100
(2.54)
.550
(13.97)
PC BOARD DRILL PATTERN
BOTTOM VIEWS
HOLE
"A"
= .081
±
.005 Dia.
(2.06 x .13)
HOLE
"B"
= .043
±
.08 Dia.
(1.09 x .08)
CLASS
9A
RELAY
30 AMP SWITCHING.
CLASS "F" INSULATION.
PC or FLANGE MOUNTED.
EPOXY SEALED WITH
REMOVABLE TAPE SEAL
OVER VENT HOLE
(REMOVED AFTER
CLEANING).
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100