SPECIFICATIONS SOLID STATE RELAY
25
40
30
35
20
15
10
5
0
1000
N
500
200
100
50
20
10
5
2
.01 .02 .05 0.1 0.2 0.5 1.0 2.0 5.0 10.0
Time in Seconds
1
75 Amps
40 Amps
10 Amps
2.5 Amps
25 Amps
Surge: Curves represent relay tolerance to load
surge currents as to magnitude and duration of
both repetitive and non-repetitive surge currents.
SURGE: OUTPUT 120 & 240 VAC
2.25
(57.2)
1.87
(47.5)
1.00
(25.4)
0.37
(9.4)
0.32
(8.1)
Dimensions shown in Inch and (Millimeter).
0.19
(4.8)
O
I
RED
L.E.D.
.175 Dia. (4.44)
(2 Holes)
Clamping Plate
4 Places
(Not used on models .996 high)
1.75
(44.45)
1.10
(27.9)
1.75
(44.5)
.215
(5.46)
OUTLINE DIMENSIONS
Input Voltage (Volts)
1
2
3
4
.49 Typ.
(12.5)
.265 max.
(6.73)
.996 max. (25.3) for 25 & 40 amp DDX models & for 75
Amp DSX & ASX models.
.800 max (20.32) for models ASX, DSX & DTX models up
to 40 Amps & DDX 12 Amp models.
UP TO 40 AMP
INPUT
3.5 mm
ABOVE 40 AMP
3.5 mm
OUTPUT
4 mm
INPUT & OUTPUT SCREW SIZE
(Shown in Millimeters)
6 mm
OUTPUT
SEE CHART
C L A S S
6
INPUT
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
NEW!
L.E.D. "ON" LAMP
UL Recognized
File No. E52197
TERMINALS
HGH
DVDT
RATNG
CLASS 6 SSR
RUGGED
CONSTRUCTON
OTERMNALS
10 20 30 DC Input Models
100 200 300 AC Input Models
AC INPUT
DC INPUT
CLASS 6
TYPICAL INPUT CURRENT
I
PAGE 102
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100