RSX 1800
SERIES
INDUSTRIAL PLUG-IN ALARM RELAY 5 AMP, 2 POLE
6
1
12
K1
K2
K2
K1
K2
K1
5
2
3
K2
K2
K1
4
K1
DS
Horn
L1
N
L1
Lamp
Alarm
M
Flasher
K1
K2
9
8
7
Reset
No trouble
R
SF T
A
N
Flasher
Acknowledge
1- Normal
2- Alarm
3- Acknowledge
4- Alarm Contact
Recloses
5- Lamp Out
Automatic
Reset Sequence.
K1 K2
Flasher
Horn Lamp
ON
OFF
OFF
OFF
On
ON
ON
ON
On
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
Flashing
ON
OFF
ON
PAGE 36
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
Automatic or Manual
1- Normal
2- Alarm
3- Acknowledge
4-
Trouble Contact
Reopens. Auto reset
Manual reset
5- Reset
6- Lamp Test
* External Jumper supplied be Customer.
K1 K2
Flasher
Horn Lamp
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
Flashing
ON
OFF
ON
OFF
ON
1- Normal
2- Alarm
3- Acknowledge
4- Alarm Contact
Recloses
5- Reset
6- Lamp Test
K1
ON
ON
OFF
OFF
ON
ON
K2
Flasher
OFF
ON
OFF
OFF
OFF
OFF
Horn
OFF
ON
OFF
OFF
OFF
OFF
OFF
Flashing
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
Manual (Push-button)
Reset Sequence.
AUTO or MANUAL RESET
RSX1800Z
6
7
8
1
12
K1
K2
K2
K1
K2
K2
K1
5
2
3
K2
K2
K1
4
K1
DS
Horn
N
A
L1
N
L1
Lamp
Flasher
T
F
S
Alarm
M
Flasher
K1
K2
9
External Jumper
NC Alarm cont.
Acknowledge
6
7
8
1
12
K1
K2
K2
K1
K2
K2
K1
5
2
3
K2
K2
K1
4
K1
DS
Horn
N
A
NC Alarm contact
L1
N
L1
Lamp
Reset
Acknowledge
Flasher
T
F
S
R
Alarm
M
Flasher
K1
K2
9
MANUAL RESET
RSX1800S
AUTOMATIC RESET
RSX1800S
* OMIT for RESET (RSX1800Z)
MANUAL RESET (RSX1800S)
Lamp
AUTOMATIC RESET (RSX1800S)
CONTACTS
Contact Material:
Rating:
TIMING
Operate Time:
Release Time:
DIELECTRIC STRENGTH
Across open contacts:
Between all mutually
insulated current
carrying parts:
TEMPERATURE
Rated Operation:
LIFE EXPECTANCY
Mechanical:
Electrical:
MISCELLANEOUS
Enclosure:
Operating Position:
Weight:
Silver Cadmium Oxide.
5 AMP, 120Vac/30Vdc Resistive
20 mS Max. @ Nominal Voltage.
25 Milliseconds max.
20 milliseconds max.
500 V rms
1500 V rms
-10C to +70C
20 Million Operations no load
500,000 Operations @ Rated Load.
Clear polycarbonate.
Any
8.8 oz (250 g) approx.
GENERAL SPECIFICATIONS
K1
- Alarm/Silencing Relay.
K2
- Alarm/Silencing Relay.
A
- Horn & optional Flasher.
TT
- Lamp test (optional).
L1
- Line voltage.
R
- Reset (optional for
manual reset only.
S
- Horn Silence (acknowledge).
F
- Flasher (Optional).
N
- Neutral.
Relays are supplied only with the
items and wiring shown within the
rectangles in schematics.
NOTE:
For additional alarms,
jumper to like terminals as shown.
LEGEND