45
μ
PD6708
Table 7-2. Timing for Reading Transmit Data from WDB
(The minimum time after transmission start return code (0H) is set)
Transmit Data
Timing for Reading Transmit Data from WDB (
μ
s)
Mode 0
Mode 1
Mode 2
Transmit data (first byte)
Approx. 1580
Approx. 400
Approx. 290
Transmit data (second byte)
Approx. 3160
Approx. 800
Approx. 580
:
:
:
:
Transmit data (N-th byte)
Approx. 1580
×
N
Approx. 400
×
N
Approx. 290
×
N
7.2.2
Transmitting slave status address and lock address
When the
μ
PD6708 receives 0H, 4H, 5H, and 6H as control bits from the master unit, the slave status and lock address
are generated automatically and sent to the master unit. As a result, there is no necessity for the host controller to be involved
in the transmission of the slave status and lock address.
7.3
Master Reception
When a unit becomes a master unit by setting 0H, 3H, 4H, 5H, 6H, and 7H as control bits and executing the MREQ1
or MREQ2 command, and receives data, slave status and lock address from the slave unit, the following will occur.
(1)
When the master unit returns an acknowledge in the message length field, the slave address, control bits and message
length bits are placed in the read data buffer (RDB) by the MREQ1 command as shown in Figure 7-4, the “master reception
start” return code (6H) is placed in STR, and an interrupt request is generated.
Figure 7-4. Data Exchange During Master Reception (Contents of RDB)
(2)
(3)
Each time one byte of receive data is received, it is placed in RDB.
Each time 20 bytes (RDB capacity) of receive data are received, if RDB is full, a “master receive buffer full” return code
(5H) is placed in STR, and an interrupt request is generated.
After one frame of data is placed in RDB, a “master reception normal termination” return code (6H) is placed in STR
and an interrupt request is generated.
If a communication error occurs during reception and communication stops without receiving all of the data transmitted
from the slave unit, a “termination during master reception” return code (7H) is placed in STR and an interrupt request
is generated.
(4)
(5)
The areas where
μ
PD6708 places receive data, etc., in RDB are shown below.
Slave Address (12 Bits)
First Byte
Second Byte
Third Byte
Fourth Byte Onward
RDB
Message Length Bits
Control Bits
相關(guān)PDF資料
PDF描述
UPD6708CX IEBusa Inter Equipment Busa PROTOCOL CONTROL LSI
UPD6708GS IEBusa Inter Equipment Busa PROTOCOL CONTROL LSI
UPD6951 6 BIT D/A CONVERTER FOR VIDEO SIGNAL PROCESSING CMOS LSI
UPD6951C 6 BIT D/A CONVERTER FOR VIDEO SIGNAL PROCESSING CMOS LSI
UPD6951G 6 BIT D/A CONVERTER FOR VIDEO SIGNAL PROCESSING CMOS LSI
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
UPD6708CX 制造商:NEC 制造商全稱:NEC 功能描述:IEBusa Inter Equipment Busa PROTOCOL CONTROL LSI
UPD6708GS 制造商:NEC 制造商全稱:NEC 功能描述:IEBusa Inter Equipment Busa PROTOCOL CONTROL LSI
UPD6708GS(A) 制造商:Renesas Electronics Corporation 功能描述:
UPD67100 制造商:未知廠家 制造商全稱:未知廠家 功能描述:ASIC
UPD67101 制造商:未知廠家 制造商全稱:未知廠家 功能描述:ASIC