TSL12S, TSL13S, TSL14S
LIGHT-TO-VOLTAGE CONVERTERS
TAOS051E SEPTEMBER 2007
2
r
r
Copyright E 2007, TAOS Inc.
The LUMENOLOGY r Company
www.taosinc.com
Available Options
DEVICE
T
A
PACKAGE LEADS
PACKAGE DESIGNATOR
ORDERING NUMBER
TSL12S
0癈 to 70癈
3-lead Sidelooker
S
TSL12S
TSL12S
0癈 to 70癈
3-lead Sidelooker Lead (Pb) Free
S
TSL12SLF
TSL12S
0癈 to 70癈
3-lead Surface-Mount Sidelooker Lead (Pb) Free
SM
TSL12SMLF
TSL13S
0癈 to 70癈
3-lead Sidelooker
S
TSL13S
TSL13S
0癈 to 70癈
3-lead Sidelooker Lead (Pb) Free
S
TSL13SLF
TSL13S
0癈 to 70癈
3-lead Surface-Mount Sidelooker Lead (Pb) Free
SM
TSL13SMLF
TSL14S
0癈 to 70癈
3-lead Sidelooker
S
TSL14S
TSL14S
0癈 to 70癈
3-lead Sidelooker Lead (Pb) Free
S
TSL14SLF
TSL14S
0癈 to 70癈
3-lead Surface-Mount Sidelooker Lead (Pb) Free
SM
TSL14SMLF
Terminal Functions
TERMINAL
NAME
NO.
TYPE
DESCRIPTION
GND
1
Power supply ground (substrate). All voltages are referenced to GND.
OUT
3
O
Output voltage.
V
DD
2
Supply voltage.
Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
DD
(see Note 1)
6 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current, I
O
?0 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Duration of short-circuit current at (or below) 25癈 (see Note 2)
5 s
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
25癈 to 85癈
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
25癈 to 85癈
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds (S Package)
260癈
. . . . . . . . . . . . . . . . . . . .
Reflow solder, in accordance with J-STD-020C or J-STD-020D (SM Package)
260癈
. . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:  1.  All voltages are with respect to GND.
2.  Output may be shorted to supply.
Recommended Operating Conditions
MIN
NOM
MAX
UNIT
Supply voltage, V
DD
2.7
5.5
V
Operating free-air temperature, T
A
0
70
癈