參數(shù)資料
型號(hào): TMDS3780514A
廠商: Texas Instruments, Inc.
英文描述: TMS370 MICROCONTROLLER FAMILY DATA BOOK
中文描述: TMS370微控制器系列數(shù)據(jù)手冊(cè)
文件頁(yè)數(shù): 31/78頁(yè)
文件大?。?/td> 919K
代理商: TMDS3780514A
TIMING CONVENTIONS
1–23
POST OFFICE BOX 1443
HOUSTON, TEXAS 77251–1443
timing conventions
This section defines the timing parameters, including cycle time, hold time, pulse duration, and others.
time intervals
New or revised data sheets in this book use letter symbols in accordance with standards recently adopted by
JEDEC, the IEEE, and the IEC. Two basic forms of symbols are used. The first form is used usually when
intervals can be classified easily as cycle, hold, setup, transition, valid, or delay times and for pulse durations.
The second form can be used generally, but in this book the second form is primarily for time intervals not easily
classifiable. The second (unclassified) form is described first. Since some manufacturers use this form for all
time intervals, symbols in the unclassified form are given with the examples for most of the classified time
intervals.
unclassified time intervals
Generalized letter symbols can be used to identify almost any time interval without classifying it using traditional
or contrived definitions. Symbols for unclassified time intervals identify two signal events listed in from-to
sequence using the format:
t
(AB-CD)
Subscripts A and C indicate the names of the signals for which changes of state or level or establishment of
state or level constitute signal events assumed to occur first and last, respectively, that is, at the beginning and
end of the time interval.
Subscripts B and D indicate the direction of the transitions and/or the final states or levels of the signals
represented by A and C, respectively. One or two of the following is used:
H = high or transition to high
L = low or transition to low
V = a valid steady-state level
X = unknown, changing, or “don’t care” level
Z = high-impedance (off) state
The hyphen between the B and C subscripts is omitted when no confusion is likely to occur.
classified time intervals
Because of the information contained in the definitions, frequently the identification of one or both of the two
signal events that begin and end the intervals can be shortened significantly compared to the unclassified forms.
For example, it is not necessary to indicate in the symbol that an access time ends with valid data at the output.
However, if both signals are named (e.g., in a hold time), the from-to sequence is maintained.
cycle time
The time interval between the start and end of a cycle.
NOTE: For each cycle time (tc), the value given represents the minimum time interval required to complete one cycle of the given function
(e.g., read, write, etc.) correctly.
Example symbology:
Classified
t
c
t
c(SPC)
t
c(SCC)
Description
Cycle time, (SYSCLK)
Cycle time, (SPICLK)
Cycle time, (SCICLK)
相關(guān)PDF資料
PDF描述
TMDS3788828 TMS370 MICROCONTROLLER FAMILY DATA BOOK
TMDS3788844 3M710 INSERTION CUT TOOL
TMDS3788868 TMS370 MICROCONTROLLER FAMILY DATA BOOK
TMG5C80C Through Hole/Non-isolated
TMOD0110G 10 Gbits/s Modulator Driver(10 G位/秒調(diào)制驅(qū)動(dòng)器)
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
TMDS3788828 制造商:TI 制造商全稱:Texas Instruments 功能描述:TMS370 MICROCONTROLLER FAMILY DATA BOOK
TMDS3788844 制造商:TI 制造商全稱:Texas Instruments 功能描述:TMS370 MICROCONTROLLER FAMILY DATA BOOK
TMDS3788868 制造商:TI 制造商全稱:Texas Instruments 功能描述:TMS370 MICROCONTROLLER FAMILY DATA BOOK
TMDS3P603070 功能描述:EVALUTION MODULE RoHS:否 類別:編程器,開發(fā)系統(tǒng) >> 過時(shí)/停產(chǎn)零件編號(hào) 系列:- 標(biāo)準(zhǔn)包裝:1 系列:*
TMDS3P701016 制造商:Rochester Electronics LLC 功能描述:- Bulk