![](http://datasheet.mmic.net.cn/370000/TIBPAL16L8-5CJ_datasheet_16741469/TIBPAL16L8-5CJ_10.png)
ns
Pulse duration, clock
tw
TIBPAL16R4-5C, TIBPAL16R6-5C
HIGH-PERFORMANCE
IMPACT-X
PAL
CIRCUITS
SRPS011D – D3359, OCTOBER 1989 – REVISED SEPTEMBER 1992
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
10
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
(see Note 1)
Input voltage (see Note 1)
Voltage applied to disabled output (see Note 1)
Operating free-air temperature range
Storage temperature range
7 V
5.5 V
5.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0
°
C to 75
°
C
–65
°
C to 150
°
C
NOTE 1: These ratings apply except for programming pins during a programming cycle or during a preload cycle.
recommended operating conditions
MIN
4.75
NOM
MAX
5.25
5.5
0.8
–3.2
24
125
UNIT
V
V
V
mA
mA
MHz
VCC
VIH
VIL
IOH
IOL
fclock
Supply voltage
High-level input voltage (see Note 2)
Low-level input voltage (see Note 2)
High-level output current
Low-level output current
Clock frequency
5
2
0
4
4
High
Low
tsu
th
TA
NOTE 2: These are absolute voltage levels with respect to the ground pin of the device and include all overshoots due to system and/or tester
noise. Testing these parameters should not be attempted without suitable equipment.
Setup time, input or feedback before clock
↑
Hold time, input or feedback after clock
↑
Operating free-air temperature
4.5
ns
ns
°
C
0
0
25
75