3
SY88993V
Micrel, Inc.
M9999-082205
hbwhelp@micrel.com or (408) 955-1690
T
A = –40°CTA = 0°CTA = +25°CTA = +85°C
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
Unit
I
CC
Power Supply
5V
—
40
—
40
—
34
40
—
45
mA
Current(1)
3.3V
—
35
—
35
—
30
35
—
40
I
IL
/EN Input LOW
–0.3(6)
—
–0.3(6)
—
–0.3(6)
—
–0.3(6)
—mA
Current
I
IH
/EN Input HIGH
—
20(4)
—20(4)
——
20(4)
—20(4)
A
Current
—
100(5)
—
100(5)
—
100(5)
—
100(5)
I
OH
LOS Output Leakage(2)
—
100
—
100
—
100
—
100
uA
LOS
LVL
LOS
LVL Level
V
REF
V
CC
V
REF
V
CC
V
REF
—V
CC
V
REF
V
CC
V
OL
LOS Output Low
—
0.5
—
0.5
—
0.5
—
0.5
V
Level(3)
V
REF
Reference Voltage
V
CC –1.38 VCC –1.26 VCC –1.38
V
CC –1.26
V
CC –1.38
V
CC –1.32
V
CC –1.26
V
CC –1.38 VCC –1.26
V
IH
/EN Input HIGH Voltage
2.0
—
2.0
—
2.0
—
2.0
—
V
IL
/EN Input LOW Voltage
—
0.8
—
0.8
—
0.8
—
V
OFFSET Differential Output
—
±80
—
±80
—
±10
±80
—
±80
mV
Offset
V
CMR
Common Mode Range
GND
±2V
CC–0.2
GND
±2V
CC–0.2
GND
±2—
V
CC–0.2
GND
±2V
CC–0.2
V
DC ELECTRICAL CHARACTERISTICS
V
CC = +3.3V ±10% or +5V ±10%, RLOAD = 50 to VCC
Notes:
1. No output load.
2. V
OH = 5.5V.
3. I
OL = +2mA.
4. V
IN = 2.7V
5. V
IN = VCC
6. V
IN = 0.5V
Symbol
Rating
Value
Unit
V
CC
Power Supply Voltage
0 to +7.0
V
D
IN, /DIN
Input Voltage
0 to V
CC
V
T
A
Operating Temperature Range
–40 to +85
°C
T
store
Storage Temperature Range
–55 to +125
°C
ABSOLUTE MAXIMUM RATINGS(1)
Note:
1. Permanent device damage may occur if absolute maximum ratings are exceeded. This is a stress rating only and functional operation is not implied at
conditions other than those detailed in the operational sections of this data sheet. Exposure to absolute maximum ratlng conditions for extended periods
may affect device reliability.