SMH4046
CONFIGURATION REGISTERS (CONTINUED)
Preliminary Information
Summit Microelectronics, Inc
2082 1.7 08/23/04
29
Register R0F – Command and Control Configuration Settings
Register R0F
D7
D6
D5
D4
0
-
-
-
1
-
-
-
0
-
-
1
-
-
-
-
0
-
-
-
1
-
-
-
-
0
-
-
-
1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Register R10 – PUPA Configuration.
Register R10
D7
D6
D5
D4
0
-
-
-
1
-
-
-
-
0
0
0
-
0
0
1
-
0
1
0
-
0
1
1
-
1
0
0
-
1
0
1
-
1
1
0
-
1
1
1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
D3
-
-
-
-
-
-
-
-
0
1
-
-
-
-
-
-
D2
-
-
-
-
-
-
-
-
-
-
0
1
-
-
-
-
D1
-
-
-
-
-
-
-
-
-
-
-
-
0
1
-
-
D0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0
1
Action
Don’t wait for VCC3 out of fault before sequencing.
Wait for VCC3 out of fault before sequencing.
No write command required for Active Control.
Write command required for Active Control.
Auto Monitor actions wait for ADOC ready.
Auto Monitor actions don’t wait for ADOC ready.
Sequence off in reverse order.
Sequence off in same order.
Power off required to clear a Forced Shutdown.
Power off not required to clear a Forced Shutdown.
Abort not allowed during power off.
Abort allowed during power off.
Don’t wait for 12VIN out of fault before sequencing.
Wait for 12VIN out of fault before sequencing.
Don’t wait for VDD out of fault before sequencing.
Wait for VDD out of fault before sequencing.
D3
-
-
-
-
-
-
-
-
-
0
0
1
1
-
-
-
-
D2
-
-
-
-
-
-
-
-
-
0
1
0
1
-
-
-
-
D1
-
-
-
-
-
-
-
-
-
-
-
-
-
0
0
1
1
D0
-
-
-
-
-
-
-
-
-
-
-
-
-
0
1
0
1
Action
Channel A not used in sequencing
Channel A used in sequencing
Channel A assigned to sequence position 0
Channel A assigned to sequence position 1
Channel A assigned to sequence position 2
Channel A assigned to sequence position 3
Channel A assigned to sequence position 4
Channel A assigned to sequence position 5
Unused
Null position (not used in sequencing)
Channel A power-on delay time = 1mS
Channel A power-on delay time = 20mS
Channel A power-on delay time = 40mS
Channel A power-on delay time = 75mS
Channel A power-off delay time = 1mS
Channel A power-off delay time = 20mS
Channel A power-off delay time = 40mS
Channel A power-off delay time = 75mS