![](http://datasheet.mmic.net.cn/370000/OR2T04A-2PS84_datasheet_16726875/OR2T04A-2PS84_148.png)
Data Sheet
June 1999
ORCA Series 2 FPGAs
148
Lucent Technologies Inc.
Timing Characteristics
(continued)
Note: Speed grades of -5, -6, and -7 are for OR2TxxA devices only.
Table 41A. OR2CxxA and OR2TxxA PFU Output MUX, PLC BIDI, and Direct Routing Timing Characteristics
OR2CxxA Commercial: V
DD
= 5.0 V ± 5%, 0 °C
≤
T
A
≤
70 °C; OR2CxxA Industrial: V
DD
= 5.0 V ± 10%, –40 °C
≤
T
A
≤
+85 °C.
OR2TxxA Commercial: V
DD
= 3.0 V to 3.6 V, 0 °C
≤
T
A
≤
70 °C; OR2TxxA Industrial: V
DD
= 3.0 V to 3.6 V, –40 °C
≤
T
A
≤
+85
°C.
Parameter
Symbol
Speed
Unit
-2
-3
-4
-5
-6
-7
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
PFU Output MUX
(T
J
= 85 °C, V
DD
= min)
Output MUX Delay (F[3:0]/Q[3:0] to O[4:0]) OMUX_DEL
PLC 3-Statable BIDIs
(T
J
= 85 °C, V
DD
= min)
BIDI Propagation Delay
BIDI 3-state Enable/Disable Delay
Direct Routing
(T
J
= 85 °C, V
DD
= min)
PFU to PFU Delay (xSW)
PFU Feedback (xSW)
—
1.1
—
0.8
—
0.6
—
0.5
—
0.4
—
0.4
ns
TRI_DEL
TRIEN_DEL
—
—
1.2
1.7
—
—
1.0
1.3
—
—
0.8
1.0
—
—
0.7
0.8
—
—
0.6
0.8
—
—
0.5
0.7
ns
ns
DIR_DEL
FDBK_DEL
—
—
1.4
1.0
—
—
1.1
0.8
—
—
0.9
0.7
—
—
0.7
0.6
—
—
0.6
0.5
—
—
0.6
0.5
ns
ns
Table 41B. OR2TxxB PFU Output MUX, PLC BIDI, and Direct Routing Timing Characteristics
OR2TxxB Commercial: V
DD
= 3.0 V to 3.6 V, 0 °C
≤
T
A
≤
70 °C; OR2TxxA Industrial: V
DD
= 3.0 V to 3.6 V, –40 °C
≤
T
A
≤
+85
°C.
Parameter
Symbol
Speed
Unit
-7
-8
Min
Max
Min
Max
PFU Output MUX
(T
J
= 85 °C, V
DD
= min)
Output MUX Delay (F[3:0]/Q[3:0] to O[4:0])
PLC 3-Statable BIDIs
(T
J
= 85 °C, V
DD
= min)
BIDI Propagation Delay
BIDI 3-state Enable/Disable Delay
Direct Routing
(T
J
= 85 °C, V
DD
= min)
PFU to PFU Delay (xSW)
PFU Feedback (xSW)
OMUX_DEL
—
0.4
—
0.4
ns
TRI_DEL
TRIEN_DEL
—
—
0.7
1.1
—
—
0.6
0.9
ns
ns
DIR_DEL
FDBK_DEL
—
—
0.6
0.4
—
—
0.5
0.4
ns
ns