代理商: MAX1668
be 4in to 8in (typ) or more as long as the worst noise
sources (such as CRTs, clock generators, memory
buses, and ISA/PCI buses) are avoided.
2) Do not route the DXP_ to DXN_ lines next to the
deflection coils of a CRT. Also, do not route the
traces across a fast memory bus, which can easily
introduce +30°C error, even with good filtering.
Otherwise, most noise sources are fairly benign.
3) Route the DXP_ and DXN_ traces in parallel and in
close proximity to each other, away from any high-
voltage traces such as +12VDC. Leakage currents
from PC board contamination must be dealt with
carefully, since a 20M
leakage path from DXP_ to
ground causes about +1°C error.
4) Connect guard traces to GND on either side of the
DXP_ to DXN_ traces (Figure 2). With guard traces
in place, routing near high-voltage traces is no
longer an issue.
5) Route through as few vias and crossunders as possi-
ble to minimize copper/solder thermocouple effects.
6) When introducing a thermocouple, make sure that
both the DXP_ and the DXN_ paths have matching
thermocouples. In general, PC board-induced ther-
mocouples are not a serious problem. A copper-sol-
der thermocouple exhibits 3μV/°C, and it takes
about 200μV of voltage error at DXP_ to DXN_ to
cause a +1°C measurement error. So, most para-
sitic thermocouple errors are swamped out.
7) Use wide traces. Narrow ones are more inductive
and tend to pick up radiated noise. The 10mil
widths and spacings recommended in Figure 2 are
not absolutely necessary (as they offer only a minor
improvement in leakage and noise), but try to use
them where practical.
8) Copper cannot be used as an EMI shield, and only
ferrous materials such as steel work well. Placing a
copper ground plane between the DXP_ to DXN_
traces and traces carrying high-frequency noise sig-
nals does not help reduce EMI.
PC Board Layout Checklist
Place the MAX1668/MAX1805/MAX1989 as close as
possible to the remote diodes.
Keep traces away from high voltages (+12V bus).
Keep traces away from fast data buses and CRTs.
Use recommended trace widths and spacings.
Place a ground plane under the traces.
Use guard traces flanking DXP_ and DXN_ and con-
necting to GND.
Place the noise filter and the 0.1μF V
CC
bypass
capacitors close to the MAX1668/MAX1805/
MAX1989.
Add a 200
resistor in series with V
CC
for best noise
filtering (see the
Typical Operating Circuit
).
Twisted-Pair and Shielded Cables
For remote-sensor distances longer than 8in, or in partic-
ularly noisy environments, a twisted pair is recommend-
ed. Its practical length is 6ft to 12ft (typ) before noise
becomes a problem, as tested in a noisy electronics lab-
oratory. For longer distances, the best solution is a
shielded twisted pair like that used for audio micro-
phones. For example, Belden #8451 works well for dis-
tances up to 100ft in a noisy environment. Connect the
twisted pair to DXP_ and DXN_ and the shield to GND,
and leave the shield’s remote end unterminated.
Excess capacitance at DX_ _ limits practical remote-sen-
sor distances (see the
Typical Operating Characteristics
).
For very long cable runs, the cable’s parasitic capaci-
tance often provides noise filtering, so the 2200pF capac-
itor can often be removed or reduced in value.
Cable resistance also affects remote-sensor accuracy;
1
series resistance introduces about +0.5°C error.
Low-Power Standby Mode
Standby mode disables the ADC and reduces the sup-
ply-current drain to less than 12μA. Enter standby
mode by forcing the
STBY
pin low or through the
RUN/STOP bit in the configuration byte register.
Hardware and software standby modes behave almost
identically: all data is retained in memory, and the SMB
interface is alive and listening for reads and writes.
Activate hardware standby mode by forcing the
STBY
pin low. In a notebook computer, this line can be con-
nected to the system SUSTAT# suspend-state signal.
The
STBY
pin low state overrides any software conversion
command. If a hardware or software standby command
is received while a conversion is in progress, the conver-
M
Multichannel Remote/Local
Temperature Sensors
_______________________________________________________________________________________
9
MINIMUM
10mils
10mils
10mils
10mils
GND
GND
DXN_
DXP_
Figure 2. Recommended DXP_/DXN_ PC Traces
相關PDF資料
PDF描述
MAX1668MEE Multichannel Remote/Local Temperature Sensors
MAX1989MUE Multichannel Remote/Local Temperature Sensors
MAX167AENG CMOS 12-Bit A/D Converters With Track-and-Hold
MAX167BCNG CMOS 12-Bit A/D Converters With Track-and-Hold
MAX163BENG CMOS 12-Bit A/D Converters With Track-and-Hold
相關代理商/技術參數(shù)
參數(shù)描述
MAX1668EVKIT 功能描述:板上安裝溫度傳感器 Multichannel Remote/Local Temperature Sensors RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX1668EVSYS 功能描述:板上安裝溫度傳感器 Evaluation System for the MAX1668 RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX1668MEE 功能描述:板上安裝溫度傳感器 RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX1668MEE+ 功能描述:板上安裝溫度傳感器 MultiCh Remote Local RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX1668MEE+T 功能描述:板上安裝溫度傳感器 MultiCh Remote Local RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor