Nov 7, 2006
Page 1 of 4
www.power-one.com
Multi-Output HP6 Front End
and RACK-HP600 Data Sheet
HP6 Multi-Output AC-DC Front End
RACK-HP600
HP6 and RACK-HP600 Features
Compact 1U design
N+1 redundancy with hot plug capability
Up to four individually regulated outputs
I
2
C interface with interrupt capability
Hot swap with low insertion/extraction force connector
Power factor corrected
No minimum load required
5 V @ 1 A standby output
Single-wire current sharing
Self-contained ORing Diodes
Current limit and over-voltage protection
Full power up to 50o C
TUV, cTUVus & CB report
600 watts per module
Ac input with PFC
Description
The HP6 provides up to 600 Watts total output power with one to four outputs ranging from 0.8 to 12 Volts. HP600
RACKS offer hot-plug capability for up to 1200 Watts total at low line (2 +1) or 1800 Watts total at high line. Three
separate multi output power supplies are internally paralleled and will automatically current share for load
distribution. Hot-swap modules can be replaced with no system downtime.
V1
HP6 Front End Models
Volts
Amps
HP6-X8X8D2D-O
X
80
HP6-X4X8D4D-O
X
40
HP6-X8X4D4D-O
X
80
HP6-X8X4D2D-O
X
80
HP6-X4X8D2D-O
X
40
HP6-X4X4D4D-O
X
40
RACK-HP600 Designations
RACK-HP600
X
240
Output Voltage X = A (2.0V); B (3.3V); C (5V); T (2.5V); V (1.8V); W (1.5V); X (1.2V); Y (1V); Z (0.8V)
Options O = B (I
2
C); M (Output power good – TTL high); N (Power fail – TTL high); R (Reverse airflow)
Please contact Power-One for additional model combinations.
V2
V3
V4
Volts
X
X
X
X
X
X
Amps
80
80
40
40
80
40
Volts
12
12
12
12
12
12
Amps
20
40
40
20
20
40
Volts
-12
-12
-12
-12
-12
-12
Amps
3
3
3
3
3
3
X
120
12
120
-12
9