![](http://datasheet.mmic.net.cn/280000/FXP7000_datasheet_16056308/FXP7000_1.png)
FXP7000 AC-DC Series Data Sheet
MAY 31, 2005 revised to JAN 09, 2007
Page 1 of 8
www.power-one.com
Features
Three-phase AC input
Suitable for 3U or 5U height mounting
Single-wire current share or Droop current share
Remote voltage adjust and current monitoring
Overtemperature, overload, and overvoltage protection
LED supply status indicators
Current share control for up to 30 units
Standard & customized rack adaptors available
Front panel selectable-input-range
FXP7000
Front and Rear Views
The FXP7000 Series of rack-mounted power systems
provides AC front-end capability to automatic test
equipment, telecom, data communications, and other
distributed power designs. The pluggable FXP supplies
do not include an output isolation diode and may be
paralleled up to 210 kW of total output power. These
supplies provide excellent protection against input
voltage transients.
Access to interfaces for remote sensing, remote voltage
adjust, current sharing, current monitoring, power supply
status, standby voltage and inhibit, as well as power
connections, is through a connector at the rear of the
supply. The FXP has its fan, handles, voltage adjust, and
indicator lights on the front panel and a single hot-plug
connector on the rear. Airflow is from the front through
the rear. Alarm, monitoring, and control signals are
floating from the main output and can be referenced to
the positive or negative output or sense line of the power
supply. The output is floating with respect to the chassis
and may be used as a positive or negative polarity
supply.
The FXP7000 Series meets international safety
requirements and is CE Marked to the Low Voltage
Directive. This series operates on three-phase European
voltages as well as (up to) 480VAC, delta or wye.
Distributed Power Front-End
Hot-Pluggable Model
MODEL
OUTPUT
VOLTAGE
48V
INPUT VOLTAGE RANGE
3-PHASE (VAC)
180 to 264 or 342 to 528
ADJUSTMENT
RANGE
45.6V to 50.4V
MAXIMUM OUTPUT
CURRENT
145A
LINE
LOAD
INITIAL SETTING
ACCURACY
47.90V to 48.10V
REGULATION
0.15%
REGULATION (NOTE 1)
0.2%
FXP7000-48-S
NOTES:
1)
With Remote Sense connected.
Input Specifications
PARAMETER
Input Voltage - AC
DESCRIPTION/CONDITIONS
3-phase delta low input range, nominal.
3-phase delta high input range, nominal.
Continuous deviation from the above nominals.
Per phase at full rated load.
Internally limited.
MIN
200
380
-10
NOM
MAX
240
480
+10
30
38
38
60
UNITS
VAC
%
Input Current
Inrush Surge Current
FXP7000 at 180 VAC:
A
RMS
Vin = 264VAC (one cycle). 25° C:
Vin = 528VAC (one cycle). 25° C:
A
PK
Input Frequency
Hold-up Time
AC input.
After last AC line peak at full power.
50
17
13
Hz
208 VAC:
400 VAC:
ms
Operating Frequency
Power Factor
Switching frequency, fixed.
100
kHz
W/VA
0.90