參數(shù)資料
型號(hào): DS21FT40
廠商: DALLAS SEMICONDUCTOR
元件分類: Digital Transmission Controller
英文描述: DATACOM, FRAMER, PBGA300
封裝: BGA-300
文件頁(yè)數(shù): 9/87頁(yè)
文件大?。?/td> 386K
代理商: DS21FT40
DS21FT40
17 of 87
RECEIVE SIDE PINS
Signal Name:
RCLK
Signal Description:
Receive Clock Input
Signal Type:
Input
2.048 MHz clock that is used to clock data through the receive side framer.
Signal Name:
RSER
Signal Description:
Receive Serial Data
Signal Type:
Output
Received NRZ serial data. Updated on rising edges of RCLK when the receive side elastic store is
disabled. Updated on the rising edges of RSYSCLK when the receive side elastic store is enabled.
Signal Name:
RSYNC
Signal Description:
Receive Sync
Signal Type:
Input /Output
An extracted pulse, one RCLK wide, is output at this pin which identifies either frame or CAS/CRC
multiframe boundaries. If the receive side elastic store is enabled, then this pin can be enabled to be an
input at which a frame or multiframe boundary pulse synchronous with RSYSCLK is applied.
Signal Name:
RMSYNC
Signal Description:
Receive Multiframe Sync
Signal Type:
Output
An extracted pulse, one RSYSCLK wide, is output at this pin which identifies multiframe boundaries. If
the receive side elastic store is disabled, then this output will output multiframe boundaries associated
with RCLK.
Signal Name:
RSYSCLK
Signal Description:
Receive System Clock
Signal Type:
Input
1.544 MHz or 2.048 MHz clock. Only used when the elastic store function is enabled. Should be tied
low in applications that do not use the elastic store. Can be burst at rates up to 8.192 MHz.
Signal Name:
RPOS
Signal Description:
Receive Positive Data Input
Signal Type:
Input
Sampled on the falling edge of RCLK for data to be clocked through the receive side framer. RPOS and
RNEG can be tied together for an NRZ interface. Connecting RPOS to RNEG disables the bipolar
violation monitoring circuitry.
Signal Name:
RNEG
Signal Description:
Receive Negative Data Input
Signal Type:
Input
Sampled on the falling edge of RCLK for data to be clocked through the receive side framer. RPOS and
RNEG can be tied together for an NRZ interface. Connecting RPOS to RNEG disables the bipolar
violation monitoring circuitry.
相關(guān)PDF資料
PDF描述
DS21FT42 DATACOM, FRAMER, PBGA300
DS21FT42N DATACOM, FRAMER, PBGA300
DS21FF42 DATACOM, FRAMER, PBGA300
DS21FF42N DATACOM, FRAMER, PBGA300
DS21FT44N DATACOM, FRAMER, PBGA300
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
DS21FT40N 制造商:Rochester Electronics LLC 功能描述: 制造商:Maxim Integrated Products 功能描述:
DS21FT42 功能描述:網(wǎng)絡(luò)控制器與處理器 IC 4x4 16/4x3 12 Chnl T1/T1 Framer RoHS:否 制造商:Micrel 產(chǎn)品:Controller Area Network (CAN) 收發(fā)器數(shù)量: 數(shù)據(jù)速率: 電源電流(最大值):595 mA 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:PBGA-400 封裝:Tray
DS21FT42N 功能描述:網(wǎng)絡(luò)控制器與處理器 IC 4x4 16/4x3 12 Chnl T1/T1 Framer RoHS:否 制造商:Micrel 產(chǎn)品:Controller Area Network (CAN) 收發(fā)器數(shù)量: 數(shù)據(jù)速率: 電源電流(最大值):595 mA 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:PBGA-400 封裝:Tray
DS21FT44 功能描述:網(wǎng)絡(luò)控制器與處理器 IC RoHS:否 制造商:Micrel 產(chǎn)品:Controller Area Network (CAN) 收發(fā)器數(shù)量: 數(shù)據(jù)速率: 電源電流(最大值):595 mA 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:PBGA-400 封裝:Tray
DS21FT44+ 功能描述:網(wǎng)絡(luò)控制器與處理器 IC 4X3 E1 Framer E1 Framer E1 Framer RoHS:否 制造商:Micrel 產(chǎn)品:Controller Area Network (CAN) 收發(fā)器數(shù)量: 數(shù)據(jù)速率: 電源電流(最大值):595 mA 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:PBGA-400 封裝:Tray