ADN4666
Rev. 0 | Page 3 of 12
SPECIFICATIONS
VCC = 3.0 V to 3.6 V, CL = 15 pF to GND, all specifications TMIN to TMAX, unless otherwise noted.1, 2 Table 1.
Parameter
Symbol
Min
Typ
Max
Unit
Test Conditions/Comments
LVDS INPUTS (RINx+, RINx)
Differential Input High Threshold at RINx+, RINx3 VTH
20
100
mV
VCM = 1.2 V, 0.05 V, 2.95 V
Differential Input Low Threshold at RINx+, RINx3 VTL
100
20
mV
VCM = 1.2 V, 0.05 V, 2.95 V
Common-Mode Voltage Range at RINx+, RINx4 VCMR
0.1
2.3
V
VID = 200 mV p-p
Input Current at RINx+, RINx
IIN
10
±5
+10
μA
VIN = 2.8 V, VCC = 3.6 V or 0 V
10
±1
+10
μA
VIN = 0 V, VCC = 3.6 V or 0 V
20
±1
+20
μA
VIN = 3.6 V, VCC = 0 V
Input High Voltage
VIH
2.0
VCC
V
Input Low Voltage
VIL
GND
0.8
V
Input Current
IIN
10
±1
+10
μA
VIN = 0 V or VCC, other input = VCC or GND
Input Clamp Voltage
VCL
1.5
0.8
V
ICL = 18 mA
OUTPUTS (ROUTx)
Output High Voltage
VOH
2.7
3.0
V
IOH = 0.4 mA, VID = 200 mV
2.7
3.0
V
IOH = 0.4 mA, input terminated
2.7
3.0
V
IOH = 0.4 mA, input shorted
Output Low Voltage
VOL
0.1
0.25
V
IOL = 2 mA, VID = 200 mV
Output Short-Circuit Current
5IOS
15
48
120
mA
Outputs enabled, VOUT = 0 V
Output Off State Current
IOZ
10
±1
+10
μA
Outputs disabled, VOUT = 0 V or VCC
POWER SUPPLY
No Load Supply, Current Receivers Enabled
ICC
10
15
mA
EN and EN = VCC or GND, inputs open
No Load Supply, Current Receivers Disabled
ICCZ
3
5
mA
EN = GND and EN = VCC, inputs open
ESD PROTECTION
RINx+, RINx Pins
±8
kV
IEC 61000-4-2 contact discharge
±15
kV
Human body model
All Pins Except RINx+, RINx
±4
kV
Human body model
1 Current into device pins is defined as positive. Current out of device pins is defined as negative. All voltages are referenced to ground, unless otherwise specified.
2 All typical values are given for VCC = 3.3 V and TA = 25°C.
3 VCC is always higher than the RINx+ and RINx voltage. RINx and RINx+ have a voltage range of 0.2 V to VCC VID/2. However, to be compliant with ac specifications, the
common-mode voltage range is 0.1 V to 2.3 V.
4 VCMR is reduced for larger input differential voltage (VID). For example, if VID is 400 mV, VCMR is 0.2 V to 2.2 V. The fail-safe condition with inputs shorted is not supported
over the common-mode range of 0 V to 2.4 V, but is supported only with inputs shorted and no external common-mode voltage applied. VID up to VCC 0 V can be
applied to the RINx+/RINx inputs with the common-mode voltage set to VCC/2. Propagation delay and differential pulse skew decrease when VID is increased from 200 mV to
400 mV. Skew specifications apply for 200 mV
≤ V
ID
≤ 800 mV over the common-mode range.
5 Output short-circuit current (IOS) is specified as magnitude only; a minus sign indicates direction only. Note that only one output should be shorted at a time; do not
exceed the maximum junction temperature specification (150°C).