–4–
ADDC02812DA/ADDC02815DA
ABSOLUT E MAX IMUM RAT INGS*
INHIBIT . . . . . . . . . . . . . . . . . . . . . . . . . . 50 V dc, –0.5 V dc
SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 V dc, –0.5 V dc
I
SHARE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 V dc, –0.5 V dc
T EMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 V dc, –0.3 V dc
Lead Soldering T emp (10 sec) . . . . . . . . . . . . . . . . . . .+300
°
C
Storage T emperature . . . . . . . . . . . . . . . . . . –65
°
C to +150
°
C
Maximum Junction T emperature . . . . . . . . . . . . . . . .+150
°
C
Maximum Case Operating T emperature . . . . . . . . . . .+125
°
C
*Absolute maximum ratings are limiting values, to be applied individually, and
beyond which the serviceability of the circuit may be impaired. Functional
operability under any of these conditions is not necessarily implied. Exposure of
absolute maximum rating conditions for extended periods of time may affect
device reliability.
REV. A
ORDE RING GUIDE
Operating
T emperature
Range (Case)
–40
°
C to +85
°
C
–55
°
C to +90
°
C
Package
Description
Model
ADDC02812DAK V
ADDC02812DAT V
5962-9684101HX C
(ADDC02812DAT V/QMLH)
ADDC02815DAK V
ADDC02815DAT V
5962-9684201HX C
(ADDC02815DAT V/QMLH)
Hermetic
Hermetic
–55
°
C to +125
°
C
–40
°
C to +85
°
C
–55
°
C to +90
°
C
Hermetic
Hermetic
Hermetic
–55
°
C to +125
°
C
Hermetic
E X PLANAT ION OF T E ST LE VE LS
T est Level
I
– 100% production tested.
II
– 100% production tested at +25
°
C, and sample tested
at specified temperatures.
III – Sample tested only.
IV
– Parameter is guaranteed by design and characterization
testing.
V
– Parameter is a typical value only.
VI
– All devices are 100% production tested at +25
°
C. 100%
production tested at temperature extremes for military
temperature devices; guaranteed by design and charac-
terization testing for industrial devices.
PIN CONFIGURAT ION
1
11
12
17
TOP
VIEW
PIN DE SCRIPT IONS
Pin
No.
Name
Function
1
–SENSE
Feedback loop connection for remote sensing
output voltage. Must always be connected for
proper operation.
Feedback loop connection for remote sensing
output voltage. Must always be connected
for proper operation.
Adjusts output voltage setpoint.
Indicates output voltage is within
±
5% of
nominal. Active high referenced to –SENSE
(Pin 1).
Low level dc auxiliary voltage supply refer-
enced to input return (Pin 10).
Power supply disable. Active low and refer-
enced to input return (Pin 10).
Clock synchronization input for multiple
units; referenced to input return (Pin 10).
Current share pin which allows paralleled
units to share current typically within
±
5% at
full load; referenced to input return (Pin 10).
Case temperature indicator and temperature
shutdown override; referenced to input return
(Pin 10).
Input Return.
+28 V Nominal Input Bus.
+12 V dc Output (ADDC02812DA).
+15 V dc Output (ADDC02815DA).
+12 V dc Output (ADDC02812DA).
+15 V dc Output (ADDC02815DA).
Output Return.
Output Return.
–12 V dc Output (ADDC02812DA).
–15 V dc Output (ADDC02815DA).
–12 V dc Output (ADDC02812DA).
–15 V dc Output (ADDC02815DA).
2
+SENSE
3
4
ADJUST
ST AT US
5
V
AUX
6
INHIBIT
7
SYNC
8
I
SHARE
9
T EMP
10
11
12
–V
IN
+V
IN
+V
OUT
13
+V
OUT
14
15
16
V
COMMON
V
COMMON
–V
OUT
17
–V
OUT
C AUT ION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the ADDC02812DA/ADDC02815DA feature proprietary ESD protection circuitry, permanent
damage may occur on devices subjected to high energy electrostatic discharges. T herefore, proper
ESD precautions are recommended to avoid performance degradation or loss of functionality.
WARNNG
ESD SENSITIVE DEVICE