15
SECTION 4
Selection of Test Voltage and Resistance Limit
Tools required – Small blade, screwdriver.
The 3M Workstation Monitor Model 724 allows for the selection of test
voltages (9V or 16V) and resistance limits (10 Megohms or 35 Megohms). The
additional ranges have been added to accommodate global ESD requirements.
Selection of the operating parameters are left up to the user’s discretion.
a) Select the desired resistance and voltage limit by moving the appropriate
slide switch (with screwdriver) on the side of the Workstation Monitor
Model 724 to the desired position (Figure 2).
SECTION 5
Mounting the 3M Workstation Monitor Model 724 and
3M Dual Conductor Remote Input Jack Model 732
a) Mount or position the Workstation
Monitor Model 724 so that the
lamps are easily viewed by the
operator (Figs. 10 and 11). Mount
the Workstation Monitor Model
724 to the underside of a work
bench top or shelf through the
two holes located at the top rear
of the case using the two screws
supplied. If using the screws is
not possible, apply an appropriate
amount of durable, double-sided
adhesive foam tape to the case.
b) Locate the Dual Conductor
Remote Input Jack Model 732
so that it is convenient for the
operators to attach their wrist strap
ground cord. Mount the remote
with the screws provided.
Figure 10 – 3M Workstation Monitor Model 724
mounted on bench top.
Figure 11 – 3M Workstation Monitor Model 724
mounted under shelf or bench.