![](http://datasheet.mmic.net.cn/190000/1894-40KLF_datasheet_14795934/1894-40KLF_7.png)
ICS1894-40
10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE
PHYCEIVER
IDT / ICS 10BASE-T/100BASE-TX INTEGRATED PHYCEIVER WITH RMII INTERFACE 7
ICS1894-40
REV C 092909
setting that is common to the two link partners is selected as
the mode of operation.
The following list shows the speed and duplex operation
mode from highest to lowest.
Priority 1: 100Base-TX, full-duplex
Priority 2: 100Base-TX, half-duplex
Priority 3: 10Base-T, full-duplex
Priority 4: 10Base-T, half-duplex
If auto-negotiation is not supported or the ICS1894-40 link
partner is forced to bypass auto-negotiation, the
ICS1894-40 sets its operating mode by observing the signal
at its receiver. This is known as parallel detection, and
allows the ICS1894-40 to establish link by listening for a
fixed signal protocol in the absence of auto-negotiation
advertisement protocol.
MII Management (MIIM) Interface
The ICS1894-40 supports the IEEE 802.3 MII Management
Interface, also known as the Management Data Input /
Output (MDIO) Interface. This interface allows upper-layer
devices to monitor and control the state of the ICS1894-40.
An external device with MIIM capability is used to read the
PHY status and/or configure the PHY settings. Additional
details on the MIIM interface can be found in Clause
22.2.4.5 of the IEEE 802.3u Specification.
The MIIM interface consists of the following:
A physical connection that incorporates the clock line
(MDC) and the data line (MDIO).
A specific protocol that operates across the
aforementioned physical connection that allows an
external controller to communicate with one or more
ICS1894-40 devices. Each ICS1894-40 device is
assigned a PHY address between 1 and 7 by the P[4:0]
strapping pins.
An internal addressable set of thirteen 16-bit MDIO
registers. Register [0:6] are required, and their functions
are defined by the IEEE 802.3u Specification. The
additional registers are provided for expanded
functionality.
The ICS1894-40 supports MIIM in both MII mode and RMII
mode.
The following table shows the MII Management frame
format for the ICS1894-40.
MII Management Frame Format
Interrupt (INT)
INT (pin 12) is an optional interrupt signal that is used to
inform the external controller that there has been a status
update in the ICS1894-40 PHY register. Bits[15:8] of
register 1Bh are the interrupt control bits, and are used to
enable and disable the conditions for asserting the INT
signal. Bits[7:0] of register 1Bh are the interrupt status bits,
and are used to indicate which interrupt conditions have
occurred. The interrupt status bits are cleared after reading
register 1Bh. Bit 9 of register 1Fh sets the interrupt level to
active high or active low.
MII Data Interface
The Media Independent Interface (MII) is specified in
Clause 22 of the IEEE 802.3u Specification. It provides a
common interface between physical layer and MAC layer
devices, and has the following key characteristics:
Supports 10Mbps and 100Mbps data rates.
Uses a 25MHz reference clock, sourced by the PHY.
Provides independent 4-bit wide (nibble) transmit and
receive data paths.
Contains two distinct groups of signals: one for
transmission and the other for reception.
By default, the ICS1894-40 is configured in MII mode after it
is power-up or reset with the following:
A 25MHz crystal connected to REF_IN, REF_OUT (pins
37, 36), or an external 25MHz clock source (oscillator)
connected to REF_IN.
Preamble Start of
Frame
Read/Write
OP Code
PHY Address
Bits [4:0]
REG Address
Bits [4:0]
TA
Data Bits
[15:0]
Idle
Read
32 1’s
01
10
00AAA
RRRRR
Z0
DDDDDDDD_DDDDDDDD
Z
Write
32 1’s
01
00AAA
RRRRR
10
DDDDDDDD_DDDDDDDD
Z