SENSITIVE PLUG-IN, 5 AMP, 1 - 3 POLES
392
SERIES
Series
Series 392 enclosed plug-in, low
power consumtion coil.
Open Style (Consult Factory)
Contact Arrangements
XAX- SPDT
XBX - DPDT
XCX - 3PDT
Construction Style
Open Style: ( Consult Factory for
mounting styles, special wiring etc.).
Enclosed Plug-in
- CODE 48P
Options
Indicator Lamp, (125 VDC coil only.see coil
specifications) -
CODE L
Manual Actuator -
CODE M
Operating Current (DC Only)
XAX: 11.1, 7.0, 5.0, 3.5 (Add M)
XBX: 15.8, 10.0, 7.0, 5.0 (Add M)
XCX: 19.3, 12.0, 8.5, 6.0 (Add M)
ORDERING CODE
Typical Type No.
392 XBX 48P LM - 5.0M
Struthers-Dunn
SEE SECTION 10 FOR MATING SOCKETS
The 392 series
relay has been designed to operate at 125 Milliwatts
per pole. Because of the coil sensitivity, the contacts are rated at 5 Amps.
The Industry standard 8 pin octal plug is used with SPDT & DPDT contact
configurations, and the 11 pin plug is used with 3PDT contact configurations.
Silver contacts are standard on this 5 Amp Relay.
1.37
(34.9)
.40
(10.1)
.675
(17.1)
2.25
(57.1)
1
5
2
6
3
7
4
8
1.37
(34.9)
OUTLINE DIMENSIONS
Dimensions are shown in INCHES and (MILLIMETERS).
CONTACTS
Contact Material:
TIMING
Operate Time:
Release Time:
DIELECTRIC STRENGTH
Across open contacts:
All Mutually Insulated current
carrying parts to ground:
Insulation Resistance:
TEMPERATURE
Rated Operation:
LIFE EXPECTANCY
Mechanical:
Electrical:
MISCELLANEOUS
Enclosure:
Weight;
Resistance
(Ohms)
11.1
7.0
5.0
3.5
1,000
2,500
5,000
10,000
15-44
23-68
32-97
45-139
SPDT
392XAX
mA Volts
15.8
10.0
7.0
5.0
21-44
32-68
45-97
64-139
19.3
12.0
8.5
6.0
25-44
39-68
55-97
77-139
COIL SPECIFICATIONS @ 25C
Silver
20 mS Max. @ Nominal Voltage.
15 mS Max. @ Nominal Voltage.
500 V rms
1500 V rms
1000 Megohms min. 500 V
-45C to +70C
10 Million Operations no load
100,000 Operations @ Rated Load.
Clear polycarbonate
3-1/2 oz. (99.2 g approx.).
3PDT
392XCX
mA Volts
DPDT
392XBX
mA Volts
NOTES:
(1) Rates for continuous operation at 25C at voltages
within listed ranges.
(2) Must operate at min. currents listed. Specify current
when ordering
POWER CONSUMPTION:
Resistive
5A
5A
120VAC
30VDC
LOAD
CONTACT RATINGS
UL Recognized
File No. E13224
3
PDT
D
PDT
SPDT
WIRING DIAGRAM
VIEWED FROM PIN END
125mW per pole @ currents
listed in the coil table.
PAGE 190
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
GENERAL SPECIFICATIONS 392