C L A S S
67
MINIATURE 5 AMP TIME DELAY RELAY
TIMING
Operating Modes Available:
Timing Adjustments Available:
Repeatability (repeat Accuracy
when Stabilized):
Reset time:
CONTACTS
Contact Configuration:
Contact Rating:
Contact Life:
Mechanical Life:
INPUT
Nominal Input Voltage:
Temperature Range (Operate):
Temperature Range (Storage):
Steady State Input Current:
PROTECTION
Reverse Polarity:
Transient:
DIELECTRIC STRENGTH
Coil to Contacts:
Across Open Contacts:
MECHANICAL
Enclosure:
Mounting:
Weight:
Special Note:
On Delay,
0.1 to 240 Seconds
±
2% max. @ Nominal Voltage, 25C
100 Milliseconds Max
DPDT ( 2 Form "C").
5 Amps @ 120VAC/28 VDC Resistive
50,000 Operations @ 120 VAC 5 Amps
Resistive
1,500,000 Operations @ 120VAC, 2 Amps
resistive Load.
12,000,000 Operations @ 120 VAC 1Amp
Resistive Load
50,000,000 Operations
12 VDC, 24 VDC
-30C to + 55C
-50C to +85C
40 mA @ 24 VDC, 80 mA @ 12 VDC
DC models only
Twice Nominal Voltage for 1 Millisecond
500 V rms
1250 V rms
Polycarbonate dust cover.
Socket Plug-in/Solder. Also Available with
P.C. Terminals.
1.2 oz. 35.2 Grams
Use 6 Pole Socket
with plug-in style
relays. .
SPECIFICATIONS CLASS 67 TIME DELAY RELAYS
.170
(4.3)
Elongated Hole .100 x .040 ( 2 x .1)
All Contact Terminals are .010 Thick
all coil terminals are .018 Thick.
1.18 Max.
(30.2)
3-48UNC-2A Thd.
.094
(2.3)
1.37
(34.9)
.734
(18.6)
.400
(10.1)
.458
(11.6)
1
4
5
6
15
14
16
7
+
-
WIRING DIAGRAM
.56
CHASSIS CUTOUT
for panel mounting.
.790
(19.8)
.280
.140
.352
.109 DIA. (2.77)
.656
VIEWED FROM PIN END
OUTLINE DIMENSIONS
Dimensions shown are in Inches and ( Millimeters).
NOMINAL
INPUT
VOLTAGE
W67CPSOX-1
W67CPSOX-2
12 VDC
24 VDC
0.1 to 30 Seconds
0.1 to 30 Seconds
TIMING
RANGE
R12-3012X2E1
R12-3024X2E1
CROSS REFERENCE
TO
POTTER & BRUMFIELD
"ON" DELAY
PART NUMBERS SHOWN ALSO
AVAILABLE THRU STOCKING DISTRIBUTION
PART
NUMBERS
CLASS 67 TIME DELAY RELAY
±
2% REPEATABILITY
DC OPERATION
PLUG-IN/SOLDER TERMINALS
UL Recognized
File No: E43641
.200 Max.
(5.1)
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 118
OTHER COIL VOLTAGES, TIMING RANGES, P.C. TERMINALS AND
4PDT CONTACT COMBINATION AVAILABLE ON SPECIAL ORDER.
120 VAC INPUT DESIGN AVAILABLE, CONTACT FACTORY.
SEE SECTION 10
FOR
MATING SOCKETS