![](http://datasheet.mmic.net.cn/190000/VX1100_datasheet_14998047/VX1100_4.png)
Parameter list/function code table
Jaguar VX
Group
No.
Name
LCD Display
Setting range
Unit
Resol.
Def.
Basic
Functions
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
to
26
27
28
29
30
Frequency command
Operating mode
Max. O/P frequency
Base freq., motor 1
Max. O/P V, motor 1
Accel. time, motor 1
Decel. time, motor 1
Torque boost, motor 1
Electronic thermal
O/L, type
Electronic O/L, level
Restart after
momentary power
supply failure
O/P freq. HI limit
O/P freq. LO limit
Min. O/P freq. (bias)
Freq. I/P ref. gain
Driving torque limit
Braking torque limit
DC inj. brk. Start frequ.
DC inj. brk. Brkg. level
DC inj. brk. Brkg. time
Pre-set multistep
frequencies 1 to 7
Intl. electronic thermal
O/L for intl. brkg. R
Slip compensation
Torque vector control
Number of motor poles
00 FREQ COMND
01 OPR METHOD
02 MAX Hz
03 BASE Hz -1
04 RATED V -1
05 ACC TIME 1
06 DEC TIME 1
07 TRQ BOOST 1
08 ELECTRN OL
09 OL LEVEL
10 RESTART
11 H LIMITER
12 L LIMITER
13 FREQ BIAS
14 FREQ GAIN
15 DRV TORQUE
16 BRK TORQUE
17 DC BRK Hz
18 DC BRK LVL
19 DC BRK t
20 MULTI Hz -1
to
26 MULTI Hz -7
27 DBR OL
28 SLIP COMP
29 TRQ VECTOR
30 MTR POLES
0 = KEYPAD,
∧ or ∨ keys
1 = TERMINAL, 0 to +10V
2 = TERMINAL, 4 to 20mA
0 = KEYPAD, RUN/STOP keys
1 = TERMINAL, (FWD) & (REV)
VX, 50-400Hz VX…P, 50-120Hz
0 = Output dependent on supply V*
320 to 480 = output V
0.01 to 3600
0.00 = ramp inhibit, or 0.01 to 3600
0.0 = auto; 0.1 to 20.0 fixed boost
0 = Inactive
1 = Active for standard motor
2 = Active for inverter-rated motor
20% to 105% of inverter rating
0 = Inactive 1
1 = Inactive 2
2 = Active, smooth recovery
3 = Active, restart at set Hz
4 = Active, restart at start Hz
VX, 0-400Hz VX…P, 0-120Hz
0.0 to 200.0%
20 to 180, 999% (999 = no limit)
0, 20 to 180, 999% (999 = no limit)
0.0 to 60.0Hz
0.0 to 100%
0.0 (brake inactive), or 0.1 to 30.0s
VX
0.00, 0.20 to 400.0Hz
VX…P 0.00, 0.20 to 120.0Hz
(0.00 = preset disabled)
0 = Inactive
1 = Active for intl. R, invrs.
≤7.5kW
2 = Inactive
-9.9Hz to +5.0Hz
0 = Inactive 1 = Active
2 to 14 (even nos. only)
—
Hz
V
s
—
A
—
Hz
%
Hz
%
s
Hz
—
Hz
—
1
0.01
0.1
—
0.01
—
1
0.1
1
0.1
0.01
—
0.1
—
2
0
50
400
6.00
0.0
[0.1]
1
3
70
0
100.0
150
[120]
100
[100]
0.0
0.00
1 [0]
0.0
0
4
Functions marked by heavy outlines can be set whilst the inverter is running. DEF = factory-set defaults. Resol = resolution.
Default values are for all inverters. Where VX…P defaults differ, they are shown in square brackets […].
* LCD display shows 0V
Approx. rated current for inverter-rated motors
PRICE
INFORMATION
AND ORDERING
PRICE
INFORMATION
AND ORDERING