Parameter
Values
Unit
Notes
+In to -In
-1.0 to 60
Vdc
+In to -In
100
Vdc
For 100 ms
PC to -In
-0.3 to 7.0
Vdc
VC to -In
-0.3 to 19.0
Vdc
+Out to -Out
-0.5 to 60.0
Vdc
Isolation voltage
2,250
Vdc
Input to output
Output current
6.3
A
Continuous
Peak output current
9.4
A
For 1 ms
Output power
336
W
Continuous
Peak output power
504
W
For 1 ms
Operating temperature
-40 to +100
°C
T-Grade; baseplate
-55 to +100
°C
M-Grade; baseplate
Storage temperature
-40 to +125
°C
T-Grade
-65 to +125
°C
M-Grade
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
Absolute Maximum Ratings
SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Input voltage range
26.0
48
55
Vdc
Max VIN = 53 V, operating from -55°C to -40°C
Input dV/dt
1
V/s
Input overvoltage turn-on
55.0
Vdc
Input overvoltage turn-off
59.5
Vdc
Input current
6.7
Adc
Input reflected ripple current
143
mA p-p
Using test circuit in Figure 10; See Figure 1
No load power dissipation
2.8
4.6
W
Internal input capacitance
4.0
F
Internal input inductance
5
nH
Input Specifications (Conditions are at 48 Vin, full load, and 25°C ambient unless otherwise specified)
Note: Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions