050912
WebSite
Europe
Europe Tel: +49 2302 662-107
Americas Tel: +1 404 699-7820
Asia
Asia Tel: +852 26 14-1108
China
China Tel: +86 21 6432 5146
www.wickmanngroup.com E-mail: sales@wickmann.com
E-mail: service@wickmannusa.com
E-mail: sales@wickmann.com.hk
E-mail: sales@wickmann.cn
3.00 A
1300
350 V
570
1.71
4.5
cURus
100 A / 350 V AC
1
17 max.
0,65
97 +2
5,9
M
MINIA
INIA
INIATURE
TURE
FFFFFUSES
USES
Dimensions (mm)
Limits for Pre-arcing Time
Permissible continuous operating current is
Permissible continuous operating current is ≤≤≤≤≤ 75
75
75 % at ambient temperature of 23
% at ambient temperature of 23
% at ambient temperature of 23 C (73.4
C (73.4
C (73.4 F).
F).
Order
Qty.
Order-
Series
Amp Code
Packaging
Amp Code
Packaging
Amp Code
Packaging
Amp Code
Packaging
Amp Code
Packaging
Information
Number
150
UL 248-14, 350 V
UL 248-14, 350 V, F
, F
Lighting Ballast Protection
Time-Current Characteristic
Quick Acting (F)
Standard
UL 248-14
CSA C22.2 No. 248.14
Approvals
cULus Recognized
Features
Special design for ballast controllers
High breaking capacity
Reduced PCB space requirements
Auto-insertable from tape
W
WebLinks
ebLinks
Further info see:
www.wickmanngroup.com
Further application info see fuseology:
www.wickmanngroup.com/download/
fuseology.pdf
Rated
Amp
Voltage
Breaking
Voltage Drop Power Dissipation Melting Integral
Approvals
Current
Code
Rating
Capacity
1.0 x I
N
1.0 x I
N
10 x I
N
max. (mV)
max. (W)
max. (A2s)
5x15 mm / No. 150
150
1 Alternate breaking capacities:
100 A / 250 V AC / 50-60 Hz / cos = 0.7-0.8
10 kA / 125 V AC / 50-60 Hz / cos = 0.7-0.8
Rated Current
1.0 x I
N
1.35 x I
N
2.0 x I
N
3.00 A
> 4 h
< 1 h
< 5 s
Specifications
Packaging
040: with mounted holders - Bulk (1000 pcs.)
043: with mounted holders - Tape/Reel (1250 pcs.)
Materials
Tube:
Glass
End Caps:
Nickel-plated brass
Plug-on Caps: Silver-plated brass
Operating T
Operating Temperature
emperature
-25 C to +70 C (consider de-rating)
Climatic T
Climatic Test
est
Damp heat, steady state
40 C / 95 % / 21 days
(IEC 60068-1,-2-1,-2-2,-2-78)
Stock Conditions
+10 C to +60 C
relative humidity ≤ 75 % yearly average,
without dew, maximum value for 30 days-95 %
Vibration Resistance
24 cycles at 15 min. each (IEC 60068-2-6)
10 - 60 Hz at 0.75 mm amplitude
60 - 2000 Hz at 10 g acceleration
Solderability
235 C, 2 s (IEC 60068-2-20)
Soldering Heat Resistance
260 C, 10 s (IEC 60068-2-20)
Marking
, Current Rating, 350 V AC, 150
Unit Weight
1.5 g (approx.)
Specifications are subject
to change without notice
This product is not recommended
for new designs. Please refer to
Littelfuse No. 2200007.