Intel TXN13220/1/4/5/7/8 SFF 10 Gbps Optical Transceiver
Intel TXN13220/1/4/5/7/8 SFF 10 Gbps Optical Transceiver
Datasheet
26-Oct-2006
40
Order Number: 273807004
G15
Digital GND
In
Supply
Digital Ground
G16
TxDin12P
In
LVDS,internally 100
Ω
terminated
Transmitter (1/
16
line bit rate) data input, differential pairs.
G17
TxDin12N
In
LVDS,internally 100
Ω
terminated
Transmitter (1/16 line bit rate) data input, differential pairs.
G18
Digital GND
In
Supply
Digital Ground
G19
TxDin13P
In
LVDS,internally 100
Ω
terminated
Transmitter (1/16 line bit rate) data input, differential pairs.
G20
TxDin13N
In
LVDS,internally 100
Ω
terminated
Transmitter (1/16 line bit rate) data input, differential pairs.
G21
Digital GND
In
Supply
Digital Ground
G22
TxDin14P
In
LVDS,internally 100
Ω
terminated
Transmitter (1/16 line bit rate) data input, differential pairs.
G23
TxDin14N
In
LVDS,internally 100
Ω
terminated
Transmitter (1/
16
line bit rate) data input, differential pairs.
G24
Digital GND
In
Supply
Digital Ground
G25
TxDin15P
In
LVDS,internally 100
Ω
terminated
Transmitter (1/
16
line bit rate) data input, differential pairs.
G26
TxDin15N
In
LVDS,internally 100
Ω
terminated
Transmitter (1/16 line bit rate) data input, differential pairs.
G27
Digital GND
In
Supply
Digital Ground
G28
TxPICLKP
In
LVDS,internally 100
Ω
terminated
Transmitter (1/
16
line bit rate) input clock, differential pair, aligned with
input data.
G29
TxPICLKN
In
LVDS,internally 100
Ω
terminated
Transmitter (1/16 line bit rate) input clock, differential pair, aligned with
input data.
G30
Digital GND
In
Supply
Digital Ground
H1
Frame GND
In
Supply
Frame Ground
H2
Frame GND
In
Supply
Frame Ground
H3
NIC
N/A
No Internal Connection
H4
Frame GND
In
Supply
Frame Ground
H5
Frame GND
In
Supply
Frame Ground
H6
NIC
N/A
No Internal Connection
H7
Analog GND
In
Supply
Analog Ground
H8
Analog GND
In
Supply
Analog Ground
H9
NIC
N/A
No Internal Connection
H10
Analog GND
In
Supply
Analog Ground
H11
Analog GND
In
Supply
Analog Ground
H12
NIC
N/A
No Internal Connection
H13
Analog GND
In
Supply
Analog Ground
H14
Analog GND
In
Supply
Analog Ground
H15
AlmInterrupt
Out
open drain/collector Electrical “OR” of all receive and transmit alarms.
H16
Analog GND
In
Supply
Analog Ground
H17
Analog GND
In
Supply
Analog Ground
H18
NIC
N/A
No Internal Connection
Table 39. Input and Output Termination Description (Sheet 7 of 9)
Pin
Num-
ber
Symbol
I/O
Logic
Description