TPS75101-Q1,
’
75115-Q1,
’
75118-Q1,
’
75125-Q1,
’
75133-Q1 WITH POWER GOOD
TPS75301-Q1, TPS75315-Q1, TPS75318-Q1, TPS75325-Q1, TPS75333-Q1 WITH RESET
FAST-TRANSIENT-RESPONSE 1.5-A LOW-DROPOUT VOLTAGE REGULATORS
SGLS159
–
APRIL 2003
7
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating junction temperature range (unless otherwise noted)
Input voltage range
, V
I
Voltage range at EN
Maximum PG voltage (TPS751xxQ)
Maximum RESET voltage (TPS753xxQ)
Peak output current
Continuous total power dissipation
Output voltage, V
O
(OUTPUT, FB)
Operating virtual junction temperature range, T
J
Storage temperature range, T
stg
ESD rating, HBM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–
0.3 V to 5.5 V
–
0.3 V to 16.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16.5 V
16.5 V
Internally limited
See dissipation rating tables
5.5 V
–
40
°
C to 125
°
C
–
65
°
C to 150
°
C
2 kV
Stresses beyond those listed under
“
absolute maximum ratings
”
may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under
“
recommended operating conditions
”
is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltage values are with respect to network terminal ground.
DISSIPATION RATING TABLE 1
–
FREE-AIR TEMPERATURES
TA < 25
°
C
POWER RATING
ABOVE TA = 25
°
C
2.9 W
23.5 mW/
°
C
4.3 W
34.6 mW/
°
C
3 W
23.8 mW/
°
C
7.2 W
57.9 mW/
°
C
§
This parameter is measured with the recommended copper heat sink pattern on a 1-layer PCB, 5-in
×
5-in PCB, 1 oz. copper,
2-in
×
2-in coverage (4 in2).
This parameter is measured with the recommended copper heat sink pattern on a 8-layer PCB, 1.5-in
×
2-in PCB, 1 oz. copper
with layers 1, 2, 4, 5, 7, and 8 at 5% coverage (0.9 in2) and layers 3 and 6 at 100% coverage (6 in2). For more information, refer
to TI technical brief SLMA002.
PACKAGE
AIR FLOW
(CFM)
DERATING FACTOR
TA = 70
°
C
POWER RATING
TA = 85
°
C
POWER RATING
PWP
§
0
1.9 W
1.5 W
300
2.8 W
2.2 W
PWP
0
1.9 W
1.5 W
300
4.6 W
3.8 W
recommended operating conditions
MIN
MAX
UNIT
Input voltage, VI#
Output voltage range, VO
Output current, IO
Operating virtual junction temperature, TJ
# To calculate the minimum input voltage for your maximum output current, use the following equation: VI(min) = VO(max) + VDO(max load).
2.7
5
V
1.5
5
V
0
1.5
A
°
C
–
40
125