http://www.tracopower.com
Page 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Output Specifications
Voltage set accuracy
– Output 1 (main output)
– Output 2/ 3 (aux. outputs)
± 1 %
± 4 %
Regulation
– Input variation
– Load variation (10 –90%)
– Single output models
– Dual/ triple output models
± 0.5 % max.
± 0.5 % max.
± 2 % typ. / ± 5 % max. (symmetric load)
Minimum load
– Dual/ triple output models
5 %
(main output)
Ripple and noise
(20 Mhz Bandwidth)
100 mV pk-pk max.
Current limitation
105 – 130 % of Iout max., constant current
Short circuit protection
hiccup mode, indefinite (automatic recovery)
Capacitive load
1000 μF (each output) TPM 05xxx only
4700 μF (each output) all other models
General Specifications
Temperature ranges
– Operating
– 25 °C… +70 °C ambient temp. max.
95 °C
(over temp. protected)
55 °C
(TPM 5/ 10 models)
50 °C
(TPM 15/30 models)
– 40 °C… +100 °C
– Case
– Derating 5 % / °C above
– Storage (non operating)
Temperature coefficient
0.01 % / °C
Efficiency
70 – 80 %
(depending on model)
Humidity
(non condensing)
95 % rel max.
Switching frequency
100 kHz typ. (Puls width modulation PWM)
Hold-up time
– Vin = 115 VAC
– Vin = 230 VAC
50 ms min.
50 ms min.
Isolation voltage
– Input/ Output
3‘300 VAC
Reliability /calculated MTBF
(MIL-HDBK-217E)
> 150‘000 h @ 40°C
EMI / RFI conducted
EN 55022, class B, FCC part 15, level B
EMC compliance
– Electrostatic discharge ESD
– RF field susceptibility
– Electrical fast transients/ bursts on mainsline
– Surge
IEC / EN 61000-4-2 4 kV / 8 kV
IEC / EN 61000-4-3 10 V/m
IEC / EN 61000-4-4 2 kV
IEC / EN 61000-4-5 2 kV sym.
Safety Class II
to IEC / EN 60536
Safety standards
UL 1950, IEC 60950, EN 60950
Safety approval
cUL /UL (E172055)
Case material
CELANEX 2360 FL
(flammability to UL 94-V0)
MiniSwitcher