TMX AP46
SAW Bandpass Filter – CDMA / PCS BTS – Tx – IF
st
Preliminary Specification (rev -)
September 1 , 2006
Technical Characteristics
Operating Temperature range : [-40°C ; +85°C]
Electrical Parameters
Unit
Minimum
(1)
Typical
(1)
Maximum
(1)
Source Impedance (single ended)
-
50
(2)
-
Load Impedance (single ended)
-
50
(2)
-
Center Frequency fo
MHz
-
114.99
-
Bandwidth at –1.5 dB
(3)
MHz
1.3
1.59
1.8
Bandwidth at –5 dB
(3)
MHz
1.54
1.80
2.02
Bandwidth at –15 dB
(3)
MHz
1.82
2.08
2.3
Template on the amplitude, reference is insertion loss at fo
Attenuation at fo ± 1.225 MHz
dB
35
60
-
Attenuation at fo ± 1.275 MHz
dB
50
57
-
Ultimate attenuation
(4)
dB
45
52
-
Insertion Loss at fo
(2)
dB
-
19
24
Amplitude Variation within fo ± 0.615 MHz
(5)
dBp-p
-
0.4
0.75
Phase linearity within fo ± 0.615 MHz
degp-p
-
2
6
Group Delay variation within fo ± 0.615 MHz
nsp-p
-
170
250
Triple Transit Suppression
dB
30
40
-
Input/Output Return Loss at fo
(2)
dB
10
14
-
Temperature Coefficient
ppm/°C
2
-
-0.035
-
Notes :
(1) Typical values are nominal performance at room temperature. Minimum and maximum values take into account the variations over
temperature range and the variations of standard matching elements (
± 2% for inductors and ± 5% for capacitors and resistors)
(2) With external matching network.
(3) The amplitude reference is insertion loss at fo.
(4) Ultimate rejection is defined from 400 MHz to 1 GHz
(5) The amplitude variation is defined as the maximum level – minimum level over the given bandwidth.
(6) The nominal value will be confirmed after prototypes delivery.
Matching Network for 50
/ 50 Single Ended Configuration
L1
)
L2
10
5
Input
50
Single Ended
Output
50
Single Ended
R2
C2
C1
R1
6
1
GND
Temex Test Fixture
L1 = 68 nH, Q > 40
C1 = 75 pF ,
R1 = 820
L2 = 82 nH, Q > 40
C1 = 51 pF ,
R1 = 1470
The given configuration and values are for indication only . They may be different on the customer PC board.
TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum performance and cost.
2