![](http://datasheet.mmic.net.cn/370000/TLV2774QDRQ1_datasheet_16742115/TLV2774QDRQ1_4.png)
SGLS179B SEPTEMBER 2003 REVISED APRIL 2006
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
DD
(see Note 1)
Differential input voltage, V
ID
(see Note 2)
Input voltage range, V
I
(any input, see Note 1)
Input current, I
I
(any input)
Output current, I
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total current into V
DD+
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total current out of GND
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Duration of short-circuit current (at or below) 25
°
C (see Note 3)
Continuous total power dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: Q suffix
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
V
DD
0.3 V to V
DD
±
4 mA
±
50 mA
±
50 mA
±
50 mA
unlimited
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
See Dissipation Rating Table
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
°
C to 125
°
C
65
°
C to 150
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values, except differential voltages, are with respect to GND.
2. Differential voltages are at the noninverting input with respect to the inverting input. Excessive current flows when input is brought
below GND 0.3 V.
3. The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum
dissipation rating is not exceeded.
ESD RATING TABLE
Human Body Model
2 (H1C)
kV
ESD rating (4)
Charged-Device Model
1 (C5)
Machine Model
150 (M2)
V
NOTE 4: ESD protection level per AEC Q100 Classification TLV2771QDBVRQ1
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25 C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
5.8 mW/
°
C
°
TA = 70 C
POWER RATING
°
TA = 85 C
POWER RATING
°
TA = 125 C
POWER RATING
D
725 mW
464 mW
377 mW
145 mW
DBV
437 mW
3.5 mW/
°
C
280 mW
227 mW
87 mW
PW
700 mW
5.6 mW/
°
C
448 mW
364 mW
140 mW
recommended operating conditions
Q SUFFIX
MIN
2.5
UNIT
MAX
Supply voltage, VDD
Input voltage range, VI
Common-mode input voltage, VIC
Operating free-air temperature, TA
6
V
GND
VDD+ 1.3
VDD+ 1.3
125
V
GND
V
°
C
40