TLE2141, TLE2141A, TLE2141Y
EXCALIBUR LOW-NOISE HIGH-SPEED
PRECISION OPERATIONAL AMPLIFIERS
SLOS062D – NOVEMBER 1990 – REVISED AUGUST 1994
5–5
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC+
(see Note 1)
Supply voltage, V
CC–
Differential input voltage, V
ID
(see Note 2)
Input voltage range, V
I
(any input)
Input current, I
I
(each input)
Output current, I
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total current into V
CC+
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total current out of V
CC–
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Duration of short-circuit current at (or below) 25
°
C (see Note 3)
Continuous total dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: C suffix
I suffix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M suffix
Storage temperature range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Case temperature for 60 seconds: FK package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D or P package
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG package
22 V
–22 V
±
44 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V
CC+
to V
CC–
– 0.3 V
±
1
mA
±
80 mA
80 mA
80 mA
unlimited
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
See Dissipation Rating Table
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0
°
C to 70
°
C
–40
°
C to 105
°
C
–55
°
C to 125
°
C
–65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
260
°
C
260
°
C
300
°
C
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values, except differential voltages, are with respect to the midpoint between VCC+ and VCC–.
2. Differential voltages are at IN+ with respect to IN–. Excessive current flows if input is brought below VCC– – 0.3 V.
3. The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum
dissipation rating is not exceeded.
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
5.8 mW/
°
C
11.0 mW/
°
C
8.4 mW/
°
C
8.0 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 105
°
C
POWER RATING
TA = 125
°
C
POWER RATING
D
FK
JG
P
725 mW
1375 mW
1050 mW
1000 mW
464 mW
880 mW
672 mW
640 mW
261 mW
495 mW
378 mW
360 mW
145 mW
275 mW
210 mW
200 mW
recommended operating conditions
C SUFFIX
MIN
±
2
0
I SUFFIX
MIN
±
2
0
M SUFFIX
MIN
±
2
0
UNIT
MAX
±
22
2.9
MAX
±
22
2.7
MAX
±
22
2.7
Supply voltage, VCC
±
V
Common-mode input voltage VIC
Common-mode input voltage, VIC
VCC = 5 V
VCC
±
=
±
15 V
V
–15
12.9
–15
12.7
–15
12.7
Operating free-air temperature, TA
0
70
–40
105
–55
125
°
C