μ
SLOS193B FEBRUARY 1997 REVISED MAY 2004
5
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC+
(see Note 1)
Supply voltage, V
CC
Differential input voltage, V
ID
(see Note 2)
Input voltage range, V
I
(any input)
Input current, I
I
(each input)
Output current, I
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total current into V
CC+
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total current out of V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Duration of short-circuit current at (or below) 25
°
C (see Note 3)
Package thermal impedance,
θ
JA
(see Notes 4 and 5): D package (8-pin)
19 V
19 V
±
38 V
±
V
CC
±
1 mA
±
80 mA
80 mA
80 mA
unlimited
97.1
°
C/W
86.2
°
C/W
79.7
°
C/W
84.6
°
C/W
113
°
C/W
5.6
°
C/W
15.1
°
C/W
14.5
°
C/W
14.7
°
C/W
10
°
C/W
0
°
C to 70
°
C
40
°
C to 85
°
C
55
°
C to 125
°
C
65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
D package (14-pin)
N package
. . . . . . . . . . . . . . . . . . . . . . . . . .
P package
. . . . . . . . . . . . . . . . . . . . . . . . . .
PW package
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
J package
. . . . . . . . . . . . . . . . . . . . . . . . . .
JG package
. . . . . . . . . . . . . . . . . . . . . . . . .
U package
. . . . . . . . . . . . . . . . . . . . . . . . . .
W package
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M suffix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Case temperature for 60 seconds: FK package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D, P, or PW package
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG, U, or W package
. . . . . . . . . . . . . . . . . .
Package thermal impedance,
θ
JC
(see Notes 4 and 5): FK package
Operating free-air temperature range, T
A
: C suffix
I suffix
Storage temperature range
260
°
C
260
°
C
300
°
C
. . . . . . . . . . . .
. . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values, except differential voltages, are with respect to the midpoint between VCC+ and VCC.
2. Differential voltages are at IN+ with respect to IN.
3. The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum
dissipation rating is not exceeded.
4. Maximum power dissipation is a function of TJ(max),
θ
JA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) TA)/
θ
JA. Operating at the absolute maximum TJ of 150
°
C can affect reliability.
5. The package thermal impedance is calculated in accordance with JESD 51-7 (plastic) or MIL-STD-883 Method 1012 (ceramic).
recommended operating conditions
C SUFFIX
MIN
±
3.5
I SUFFIX
MIN
±
3.5
M SUFFIX
MIN
UNIT
MAX
±
18
MAX
±
18
MAX
±
18
Supply voltage, VCC
±
±
3.5
V
Common-mode input voltage, VIC
VCC
±
=
±
5 V
VCC
±
=
±
15 V
1.6
4
1.6
4
1.6
4
V
11
13
11
13
11
13
Operating free-air temperature, TA
0
70
40
85
55
125
°
C