TLC3702
DUAL MICROPOWER LinCMOS
VOLTAGE COMPARATORS
SLCS013D – NOVEMBER 1986 – REVISED NOVEMBER 1998
2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
AVAILABLE OPTIONS
VIOmax
at 25
°
C
PACKAGES
TA
SMALL OUTLINE
(D)
CERAMIC
(FK)
CERAMIC DIP
(JG)
PLASTIC DIP
(P)
0
°
C to 70
°
C
–40
°
C to 85
°
C
–55
°
C to 125
°
C
The D package is available taped and reeled. Add R suffix to the device type (e.g., TLC3702CDR).
5 mV
TLC3702CD
—
—
TLC3702CP
5 mV
TLC3702ID
—
—
TLC3702IP
5 mV
TLC3702MD
TLC3702MFK
TLC3702MJG
—
functional block diagram (each comparator)
VDD
GND
OUT
Differential
Input
Circuits
IN+
IN–
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
DD
(see Note 1)
Differential input voltage, V
ID
(see Note 2)
Input voltage range, V
I
Output voltage range, V
O
Input current, I
I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current, I
O
(each output)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total supply current into V
DD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total current out of GND
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: TLC3702C
TLC3702I
TLC3702M
Storage temperature range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Case temperature for 60 seconds: FK package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D or P package
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG package
–0.3 V to 18 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
18 V
–0.3 V to V
DD
– 0.3 V to V
DD
±
5 mA
±
20 mA
40 mA
40 mA
See Dissipation Rating Table
0
°
C to 70
°
C
–40
°
C to 85
°
C
–55
°
C to 125
°
C
–65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
260
°
C
260
°
C
300
°
C
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values, except differential voltages, are with respect to network ground.
2. Differential voltages are at IN+ with respect to IN–.