3
ECL Pro
SY10EP58V
SY100EP58V
Micrel, Inc.
M9999-070105
hbwhelp@micrel.com or (408) 955-1690
Absolute Maximum Ratings
(1)
Supply Voltage (V
IN
) ........................................ –6.0V to 0V
Output Current (I
OUT
)
Continuous .............................................................50mA
Surge....................................................................100mA
Lead Temperature (Soldering, 20sec.) ................... +260
°
C
Storage Temperature (T
S
) ....................... –65
°
C to +150
°
C
Operating Ratings
(2)
Supply Voltage |V
CC
–V
EE
| .......................... +3.0V to +5.5V
Ambient Temperature (T
A
)......................... –40
°
C to +85
°
C
Package Thermal Resistance
MSOP
(
θ
JA
)
Still-air ...........................................................206
°
C/W
500lfpm..........................................................155
°
C/W
SOIC
(
θ
JA
)
Still-air ..........................................................160
°
C/W
500lfpm..........................................................109
°
C/W
MSOP
(
θ
JC
) .........................................................39
°
C/W
SOIC
(
θ
JC
)..........................................................39
°
C/W
T
A
= –40
°
C
Typ.
—
—
—
—
—
—
—
T
A
= +25
°
C
Typ.
30
–0945
–1745
—
—
—
—
T
A
= +85
°
C
Typ.
—
—
—
—
—
—
—
Symbol
I
EE
V
OH
V
OL
V
IH
V
IL
I
IH
I
IL
Parameter
Min.
—
–1135
–1935
–1210
–1935
—
0.5
Max.
40
–0885
–1685
–0885
–1610
150
—
Min.
—
–1070
–1870
–1145
–1870
—
0.5
Max.
40
–0820
–1620
–0820
–1545
150
—
Min.
—
–1010
–1810
–1085
–1810
—
0.5
Max.
40
–0760
–1560
–0760
–1485
150
—
Unit
mA
mV
mV
mV
mV
μ
A
μ
A
Power Supply Current
(5)
Output HIGH Voltage
(6)
Output LOW Voltage
(6)
Input HIGH Voltage
Input LOW Voltage
Input HIGH Current
Input LOW Current
D
Notes:
1. Permanent device damage may occur if ratings in the “Absolute Maximum Ratings” section are exceeded. This is a stress rating only and functional
operation is not implied for conditions other than those detailed in the operational sections of this data sheet. Exposure to absolute maximum ratings
conditions for extended periods may affect device reliability.
2. The data sheet limits are not guaranteed if the device is operated beyond the operating ratings.
3. 10KEP circuits are designed to meet the DC specifications shown in the above table after thermal equilibrium has been established. The circuit is in
a test socket or mounted on a printed circuit board and traverse airflow greater than 500lfpm is maintained.
4. Input and output parameters vary 1:1 with V
CC
.
5. V
CC
= 0V, V
EE
= V
EE
(min) to V
EE
(max), all other pins floating.
6. All loading with 50
to V
CC
– 2.0V.
10K DC ELECTRICAL CHARACTERISTICS
(3)
V
CC
= 3.0V to 5.5V; V
EE
= 0V
(4)
V
CC
= 0V or V
EE
= –5.5V to –3.0V.
T
A
= –40
°
C
Typ.
T
A
= +25
°
C
Typ.
T
A
= +85
°
C
Typ.
Symbol
V
CC
Parameter
Min.
Max.
Min.
Max.
Min.
Max.
Unit
V
Condition
Power Supply Voltage
(PECL)
(LVPECL)
(ECL)
(LVECL)
4.5
3.0
–5.5
–3.8
—
—
5.0
—
–5.0
–3.3
35
—
5.5
3.8
–4.5
–3.0
50
75
4.5
3.0
–5.5
–3.8
—
—
5.0
—
–5.0
–3.3
35
—
5.5
3.8
–4.5
–3.0
50
75
4.5
3.0
–5.5
–3.8
—
—
5.0
—
–5.0
–3.3
35
—
5.5
3.8
–4.5
–3.0
50
80
I
EE
I
IH
I
IL
Supply Current
Input HIGH Current
Input LOW Current
mA
μ
A
No Load
V
IN
= V
IH
All Inputs
0.5
—
—
—
—
—
—
—
—
0.5
—
—
—
1.0
1.0
—
—
—
0.5
—
—
—
—
—
—
—
—
μ
A
pF
pF
V
IN
= V
IL
C
IN
Input Capacitance (MSOP)
(SOIC)
DC ELECTRICAL CHARACTERISTICS
(3)