6
Precision Edge
SY100EP14U
Micrel, Inc.
M9999-060910
hbwhelp@micrel.com or (408) 955-1690
TA = –40°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max. Unit Condition
VIL
Input LOW Voltage
3055
—
3375
3055
—
3375
3055
—
3375
mV
(Single-Ended)
VIH
Input HIGH Voltage
3775
—
4120
3775
—
4120
3775
—
4120
mV
(Single-Ended)
VOL
Output LOW Voltage
3055
3180
3305
3055
3180
3305
3055
3180
3305
mV 50 to VCC–2V
VOH
Output HIGH Voltage
3855
3980
4105
3855
3980
4105
3855
3980
4105
mV 50 to VCC–2V
VBB
Output Voltage Reference(2) 3475
3575
3675
3475
3575
3675
3475
3575
3675
mV VCC = +5.0V
VIHCMR Input HIGH Voltage(3)
2.0
—
VCC
2.0
—
VCC
2.0
—
VCC
V
Common Mode Range
(100KEP) PECL DC ELECTRICAL CHARACTERISTICS(1)
VCC = 5.0V ±10%, VEE = 0V
Note 1. 100KEP circuits are designed to meet the DC specifications shown in the above table after thermal equilibrium has been established. The
circuit is in a test socket or mounted on a printed circuit board and traverse airflow greater than 500lfpm is maintained. Input and output
parameters are at VCC = 5.0V. They vary 1:1 with VCC.
Note 2. VBB reference varies 1:1 with VCC.
Note 3. The VIHCMR range is referenced to the most positive side of the differential input signal. Single-ended input CLK pin operation is limited to VCC
≥
3.0V in PECL mode.
TA = –40°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max. Unit Condition
VIL
Input LOW Voltage
–1945
—
–1625 –1945
—
–1625 –1945
—
–1625 mV
(Single-ended)
VIH
Input HIGH Voltage
–1165
—
–880 –1165
—
–880 –1165
—
–880
mV
(Single-ended)
VOL
Output LOW Voltage
–1945 –1820 –1695 –1945 –1820 –1695 –1945 –1820 –1695 mV 50 to VCC–2V
VOH
Output HIGH Voltage
–1145 –1020 –0895 –1145 –1020 –0895 –1145 –1020 –0895 mV 50 to VCC–2V
VBB
Output Reference Voltage(2) –1525 –1425 –1325 –1525 –1425 –1325 –1525 –1425 –1325 mV
VIHCMR Input HIGH Voltage
V
Common Mode Range(3)
VEE +1.2
0.0
VEE +1.2
0.0
VEE +1.2
0.0
(100KEP) LVECL DC ELECTRICAL CHARACTERISTICS(1)
VEE = –2.37V to –3.8V; VCC = 0V
Note 1. 100KEP circuits are designed to meet the DC specifications shown in the above table after thermal equilibrium has been established. The
circuit is in a test socket or mounted on a printed circuit board and traverse airflow greater than 500lfpm is maintained. Input and output
parameters vary 1:1 with VCC.
Note 2. Single-ended input operation is limited VEE ≤ –3.0V in ECL/LVECL mode. VBB reference varies 1:1 with VCC.
Note 3. VIHCMR (min) varies 1:1 with VEE, VIHCMR (max) varies 1:1 with VCC. The VIHCMR range is referenced to the most positive side of the
differential input signal.